We have located links that may give you full text access.
Enhanced acrylic gauge with five eccentric circles for optimizing CT angiography spatial resolution via Taguchi's methodology.
Technology and Health Care : Official Journal of the European Society for Engineering and Medicine 2024 April 19
BACKGROUND: Cerebral examination via CTA is always the first choice for patients with unexpected brain injury or different types of brain lesions to detect ruptured hemangiomas, vascular infarcts, or other brain tissue lesions.
OBJECTIVE: This study innovated the acrylic gauge with five eccentric circles for computed tomography angiography (CTA) analysis to optimize the spatial resolution via Taguchi's methodology.
METHODS: The customized gauge was revised from the V-shaped slit gauge and transferred into five eccentric circles' slit gauge. The gauge was assembled with another six acrylic layers to simulate the human head. Taguchi's L18 orthogonal array was adopted to optimize the spatial resolution of CTA imaging quality. In doing so, six essential factors of CTA are kVp, mAs, spiral rotation pitch, FOV, rotation time of the CT and reconstruction filter, and each factor has either two or three levels to organize into eighteen combinations to simulate the full factor combination of 486 (21 × 35 = 486) times according to Taguchi's recommendation. Three well-trained radiologists ranked the gauge's 18 CTA scanned imaging qualities according to contrast, sharpness, and spatial resolution and derived the unique fish-bone-plot of six factors for further analysis. The optimal factor combination of CTA was proven by follow-up verification and ANOVA to obtain this study's dominant or minor factor.
RESULTS: The optimal factor combination of CTA was A2 (120 kVp), B3 (200 mAs), C1 (Pitch 0.6), D2 (FOV 220 mm2), E1 (rotation time 0.33 s), and F3 (Brain sharp, UC). Furthermore, deriving a quantified MDD (minimum detectable difference) to imply the spatial resolution of CTA, a semiauto profile analysis program run in MATLAB and OriginPro was recommended to evaluate the MDD and to suppress the manual error in calculation. Eventually, the derived MDDs of the conventional and optimal factor combinations of CTA were 2.35 and 2.26 mm, respectively, in this study.
CONCLUSION: Taguchi's methodology was found applicable for quantifying the CTA imaging quality in practical applications.
OBJECTIVE: This study innovated the acrylic gauge with five eccentric circles for computed tomography angiography (CTA) analysis to optimize the spatial resolution via Taguchi's methodology.
METHODS: The customized gauge was revised from the V-shaped slit gauge and transferred into five eccentric circles' slit gauge. The gauge was assembled with another six acrylic layers to simulate the human head. Taguchi's L18 orthogonal array was adopted to optimize the spatial resolution of CTA imaging quality. In doing so, six essential factors of CTA are kVp, mAs, spiral rotation pitch, FOV, rotation time of the CT and reconstruction filter, and each factor has either two or three levels to organize into eighteen combinations to simulate the full factor combination of 486 (21 × 35 = 486) times according to Taguchi's recommendation. Three well-trained radiologists ranked the gauge's 18 CTA scanned imaging qualities according to contrast, sharpness, and spatial resolution and derived the unique fish-bone-plot of six factors for further analysis. The optimal factor combination of CTA was proven by follow-up verification and ANOVA to obtain this study's dominant or minor factor.
RESULTS: The optimal factor combination of CTA was A2 (120 kVp), B3 (200 mAs), C1 (Pitch 0.6), D2 (FOV 220 mm2), E1 (rotation time 0.33 s), and F3 (Brain sharp, UC). Furthermore, deriving a quantified MDD (minimum detectable difference) to imply the spatial resolution of CTA, a semiauto profile analysis program run in MATLAB and OriginPro was recommended to evaluate the MDD and to suppress the manual error in calculation. Eventually, the derived MDDs of the conventional and optimal factor combinations of CTA were 2.35 and 2.26 mm, respectively, in this study.
CONCLUSION: Taguchi's methodology was found applicable for quantifying the CTA imaging quality in practical applications.
Full text links
Related Resources
Trending Papers
Hemodynamic Support in Sepsis.Anesthesiology 2024 June 2
The New Challenge of Obesity - Obesity-Associated Nephropathy.Diabetes, Metabolic Syndrome and Obesity 2024
Advances in Clinical Cardiology 2023: A Summary of Key Clinical Trials.Advances in Therapy 2024 May 15
Drug Therapy for Acute and Chronic Heart Failure with Preserved Ejection Fraction with Hypertension: A State-of-the-Art Review.American Journal of Cardiovascular Drugs : Drugs, Devices, and Other Interventions 2024 April 5
Oral Anticoagulation Use in Individuals With Atrial Fibrillation and Chronic Kidney Disease: A Review.Seminars in Nephrology 2024 May 15
Nutrition in the intensive care unit: from the acute phase to beyond.Intensive Care Medicine 2024 May 22
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app