In Vivo Findings of a Novel Focal Ablation Catheter: Focused Electric Field Catheter Tip.
JACC. Clinical Electrophysiology 2024 Februrary 20
Current catheter designs used for radiofrequency (RF) in cardiac tissue achieve limited ablation depth as lesion size is driven heavily by resistive heating at the tissue surface. A catheter with a truncated, dome-shaped tip with a toroidal surface designed for focal RF ablation was recently described. This in vivo study compares lesion characteristics between a second-generation focused electric field (FEF) catheter vs a standard irrigated catheter using RF energy in a beating heart model. We performed in vivo ablations using RF energy with the FEF ablation catheter tip (Focused Therapeutics) and an irrigated Blazer catheter (Boston Scientific) under identical power, duration, and irrigation rates. In addition, RF dosing at high power and duration was examined using the FEF catheter. Intracardiac echocardiography was used to evaluate steam pops and catheter tip angle relative to the tissue surface. Studies were terminal and lesion size was measured following 2,3,5-triphenyltetrazolium chloride staining. Ablations were performed in 6 swine (FEF = 31; control = 8). FEF ablation lesions (n = 7) were deeper (15.6 ± 2.6 mm vs 7.5 ± 1.9 mm; P < 0.001) and wider (18.4 ± 2.9 mm vs 12.6 ± 2.4 mm; P < 0.001) than lesions delivered with the control irrigated catheter (n = 8) under the same parameters. Thirty-two percent (n = 10 of 31) of lesions delivered from the left ventricle endocardial surface using the FEF catheter were transmural. No steam pops were observed with delivery of FEF lesions (n = 31). The angle of incidence did not significantly affect FEF lesion size. In this in vivo preclinical study, the FEF catheter, which provides focused energy delivery, resulted in significantly larger lesions than the irrigated control catheter without steam pops. Approximately one-third of ablations with the FEF catheter delivered from the endocardial left ventricular surface resulted in transmural lesions.
Full text links
Related Resources
Trending Papers
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Prevention and treatment of ischaemic and haemorrhagic stroke in people with diabetes mellitus: a focus on glucose control and comorbidities.Diabetologia 2024 April 17
British Society for Rheumatology guideline on management of adult and juvenile onset Sjögren disease.Rheumatology 2024 April 17
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Albumin: a comprehensive review and practical guideline for clinical use.European Journal of Clinical Pharmacology 2024 April 13
Eosinophilic Esophagitis: Clinical Pearls for Primary Care Providers and Gastroenterologists.Mayo Clinic Proceedings 2024 April
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app