We have located links that may give you full text access.
Impact of Implant Size and Position on Subsidence Degree after Anterior Cervical Discectomy and Fusion: Radiological and Clinical Analysis.
Journal of Clinical Medicine 2024 Februrary 19
BACKGROUND: Implant subsidence is recognized as a complication of interbody stabilization, although its relevance remains ambiguous, particularly in terms of relating the effect of the position and depth of subsidence on the clinical outcome of the procedure. This study aimed to evaluate how implant positioning and size influence the incidence and degree of subsidence and to examine their implications for clinical outcomes.
METHODS: An observational study of 94 patients (157 levels) who underwent ACDF was conducted. Radiological parameters (implant position, implant height, vertebral body height, segmental height and intervertebral height) were assessed. Clinical outcomes were evaluated using the Visual Analogue Scale (VAS) and Neck Disability Index (NDI). Subsidence was evaluated in groups according to its degree, and statistical analyses were performed.
RESULTS: The findings revealed that implant-to-endplate ratio and implant height were significant risk factors associated with the incidence and degree of subsidence. The incidence of subsidence varied as follows: 34 cases (41.5%) exhibited displacement of the implant into the adjacent endplate by 2-3 mm, 32 cases (39%) by 3-4 mm, 16 cases (19.5%) by ≥4 mm and 75 (47.8%) cases exhibited no subsidence.
CONCLUSIONS: The findings underscore that oversized or undersized implants relative to the disc space or endplate length elevate the risk and severity of subsidence.
METHODS: An observational study of 94 patients (157 levels) who underwent ACDF was conducted. Radiological parameters (implant position, implant height, vertebral body height, segmental height and intervertebral height) were assessed. Clinical outcomes were evaluated using the Visual Analogue Scale (VAS) and Neck Disability Index (NDI). Subsidence was evaluated in groups according to its degree, and statistical analyses were performed.
RESULTS: The findings revealed that implant-to-endplate ratio and implant height were significant risk factors associated with the incidence and degree of subsidence. The incidence of subsidence varied as follows: 34 cases (41.5%) exhibited displacement of the implant into the adjacent endplate by 2-3 mm, 32 cases (39%) by 3-4 mm, 16 cases (19.5%) by ≥4 mm and 75 (47.8%) cases exhibited no subsidence.
CONCLUSIONS: The findings underscore that oversized or undersized implants relative to the disc space or endplate length elevate the risk and severity of subsidence.
Full text links
Related Resources
Trending Papers
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Prevention and treatment of ischaemic and haemorrhagic stroke in people with diabetes mellitus: a focus on glucose control and comorbidities.Diabetologia 2024 April 17
British Society for Rheumatology guideline on management of adult and juvenile onset Sjögren disease.Rheumatology 2024 April 17
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Albumin: a comprehensive review and practical guideline for clinical use.European Journal of Clinical Pharmacology 2024 April 13
Eosinophilic Esophagitis: Clinical Pearls for Primary Care Providers and Gastroenterologists.Mayo Clinic Proceedings 2024 April
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app