Diagnostic Performance of Endoscopic Ultrasonography with Water-Filled Balloon Method for Superficial Esophageal Squamous Cell Carcinoma.
Digestive Diseases and Sciences 2023 August 5
BACKGROUND: Endoscopic ultrasonography (EUS) is a commonly used tool for preoperative depth diagnosis of superficial esophageal squamous cell carcinoma (ESCC). Probing EUS using the water-filled balloon method is a simple and safe examination.
AIM: The aim of this study was to clarify the diagnostic performance of EUS with the water-filled balloon method for superficial ESCC compared to magnifying narrow-band imaging (ME-NBI).
METHODS: We retrospectively examined 403 lesions in 393 consecutive patients diagnosed with ESCC and evaluated them with ME-NBI and EUS. Clinicopathological findings were collected, and the accuracy of the preoperative diagnosis was compared between ME-NBI and EUS-B. EUS examiners were not blinded to prior ME-NBI results, and EUS results may have been influenced by ME-NBI results.
RESULTS: The pathological tumor depth of the EP/LPM in 152 lesions, MM/SM1 in 130 lesions, and deep submucosa (SM2/SM3) in 121 lesions was examined. The proportion of total lesions with an accurate diagnosis was significantly higher in EUS than in ME-NBI (67.7% versus 62.0%, P = 0.015). When analyzed by clinical depth diagnosis using ME-NBI, the proportion of lesions with an accurate diagnosis was significantly higher for EUS in MM/SM1 (55.7% versus 46.1%, P = 0.033). The sensitivity was significantly higher in EUS for SM2/SM3 lesions (76.0% versus 54.5%, P < 0.001). The accuracy and specificity of EUS, which differentiate MM/SM1 from EP/LPM or SM2/SM3, were significantly higher than those of ME-NBI. The median endoscopic ultrasonography procedure time was approximately 6.5 min.
CONCLUSIONS: EUS with the water-filled balloon method is a safe and straightforward method that can be performed on lesions clinically diagnosed as MM/SM1 using ME-NBI. We retrospectively reviewed lesions in patients diagnosed with ESCC and evaluated them using magnifying endoscopy with narrow-band imaging (ME-NBI) and endoscopic ultrasound using the water-filled balloon method (EUS-B). We conclude that EUS-B can increase the diagnostic accuracy.
AIM: The aim of this study was to clarify the diagnostic performance of EUS with the water-filled balloon method for superficial ESCC compared to magnifying narrow-band imaging (ME-NBI).
METHODS: We retrospectively examined 403 lesions in 393 consecutive patients diagnosed with ESCC and evaluated them with ME-NBI and EUS. Clinicopathological findings were collected, and the accuracy of the preoperative diagnosis was compared between ME-NBI and EUS-B. EUS examiners were not blinded to prior ME-NBI results, and EUS results may have been influenced by ME-NBI results.
RESULTS: The pathological tumor depth of the EP/LPM in 152 lesions, MM/SM1 in 130 lesions, and deep submucosa (SM2/SM3) in 121 lesions was examined. The proportion of total lesions with an accurate diagnosis was significantly higher in EUS than in ME-NBI (67.7% versus 62.0%, P = 0.015). When analyzed by clinical depth diagnosis using ME-NBI, the proportion of lesions with an accurate diagnosis was significantly higher for EUS in MM/SM1 (55.7% versus 46.1%, P = 0.033). The sensitivity was significantly higher in EUS for SM2/SM3 lesions (76.0% versus 54.5%, P < 0.001). The accuracy and specificity of EUS, which differentiate MM/SM1 from EP/LPM or SM2/SM3, were significantly higher than those of ME-NBI. The median endoscopic ultrasonography procedure time was approximately 6.5 min.
CONCLUSIONS: EUS with the water-filled balloon method is a safe and straightforward method that can be performed on lesions clinically diagnosed as MM/SM1 using ME-NBI. We retrospectively reviewed lesions in patients diagnosed with ESCC and evaluated them using magnifying endoscopy with narrow-band imaging (ME-NBI) and endoscopic ultrasound using the water-filled balloon method (EUS-B). We conclude that EUS-B can increase the diagnostic accuracy.
Full text links
Related Resources
Trending Papers
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Prevention and treatment of ischaemic and haemorrhagic stroke in people with diabetes mellitus: a focus on glucose control and comorbidities.Diabetologia 2024 April 17
British Society for Rheumatology guideline on management of adult and juvenile onset Sjögren disease.Rheumatology 2024 April 17
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Albumin: a comprehensive review and practical guideline for clinical use.European Journal of Clinical Pharmacology 2024 April 13
Eosinophilic Esophagitis: Clinical Pearls for Primary Care Providers and Gastroenterologists.Mayo Clinic Proceedings 2024 April
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app