We have located links that may give you full text access.
Movement Competency Screens Can Be Reliable In Clinical Practice By A Single Rater Using The Composite Score.
Background: Movement competency screens (MCSs) are commonly used by coaches and clinicians to assess injury risk. However, there is conflicting evidence regarding MCS reliability.
Purpose: This study aimed to: (i) determine the inter- and intra-rater reliability of a sport specific field-based MCS in novice and expert raters using different viewing methods (single and multiple views); and (ii) ascertain whether there were familiarization effects from repeated exposure for either raters or participants.
Study Design: Descriptive laboratory study.
Methods: Pre-elite youth athletes (n=51) were recruited and videotaped while performing a MCS comprising nine dynamic movements in three separate trials. Performances were rated three times with a minimal four-week wash out between testing sessions, each in randomized order by 12 raters (3 expert, 9 novice), using a three-point scale. Kappa score, percentage agreement and intra-class correlation were calculated for each movement individually and for the composite score.
Results: Fifty-one pre-elite youth athletes (15.0±1.6 years; n =33 athletics, n =10 BMX and n =8 surfing) were included in the study. Based on kappa score and percentage agreement, both inter- and intra-rater reliability were highly variable for individual movements but consistently high (>0.70) for the MCS composite score. The composite score did not increase with task familiarization by the athletes. Experts detected more movement errors than novices and both rating groups improved their detection of errors with repeated viewings of the same movement.
Conclusions: Irrespective of experience, raters demonstrated high variability in rating single movements, yet preliminary evidence suggests the MCS composite score could reliably assess movement competency. While athletes did not display a familiarization effect after performing the novel tasks within the MCS for the first time, raters showed improved error detection on repeated viewing of the same movement.
Level of Evidence: Cohort study.
Purpose: This study aimed to: (i) determine the inter- and intra-rater reliability of a sport specific field-based MCS in novice and expert raters using different viewing methods (single and multiple views); and (ii) ascertain whether there were familiarization effects from repeated exposure for either raters or participants.
Study Design: Descriptive laboratory study.
Methods: Pre-elite youth athletes (n=51) were recruited and videotaped while performing a MCS comprising nine dynamic movements in three separate trials. Performances were rated three times with a minimal four-week wash out between testing sessions, each in randomized order by 12 raters (3 expert, 9 novice), using a three-point scale. Kappa score, percentage agreement and intra-class correlation were calculated for each movement individually and for the composite score.
Results: Fifty-one pre-elite youth athletes (15.0±1.6 years; n =33 athletics, n =10 BMX and n =8 surfing) were included in the study. Based on kappa score and percentage agreement, both inter- and intra-rater reliability were highly variable for individual movements but consistently high (>0.70) for the MCS composite score. The composite score did not increase with task familiarization by the athletes. Experts detected more movement errors than novices and both rating groups improved their detection of errors with repeated viewings of the same movement.
Conclusions: Irrespective of experience, raters demonstrated high variability in rating single movements, yet preliminary evidence suggests the MCS composite score could reliably assess movement competency. While athletes did not display a familiarization effect after performing the novel tasks within the MCS for the first time, raters showed improved error detection on repeated viewing of the same movement.
Level of Evidence: Cohort study.
Full text links
Related Resources
Trending Papers
Consensus Statement on Vitamin D Status Assessment and Supplementation: Whys, Whens, and Hows.Endocrine Reviews 2024 April 28
The Tricuspid Valve: A Review of Pathology, Imaging, and Current Treatment Options: A Scientific Statement From the American Heart Association.Circulation 2024 April 26
Intravenous infusion of dexmedetomidine during the surgery to prevent postoperative delirium and postoperative cognitive dysfunction undergoing non-cardiac surgery: a meta-analysis of randomized controlled trials.European Journal of Medical Research 2024 April 19
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Ventilator Waveforms May Give Clues to Expiratory Muscle Activity.American Journal of Respiratory and Critical Care Medicine 2024 April 25
Acute Kidney Injury and Electrolyte Imbalances Caused by Dapagliflozin Short-Term Use.Pharmaceuticals 2024 March 27
Systemic lupus erythematosus.Lancet 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app