Paramedic-performed Prehospital Point-of-care Ultrasound for Patients with Undifferentiated Dyspnea: A Pilot Study.

INTRODUCTION: Thoracic ultrasound is frequently used in the emergency department (ED) to determine the etiology of dyspnea, yet its use is not widespread in the prehospital setting. We sought to investigate the feasibility and diagnostic performance of paramedic acquisition and assessment of thoracic ultrasound images in the prehospital environment, specifically for the detection of B-lines in congestive heart failure (CHF).

METHODS: This was a prospective observational study of a convenience sample of adult patients with a chief complaint of dyspnea. Paramedics participated in a didactic and hands-on session instructing them how to use a portable ultrasound device. Paramedics assessed patients for the presence of B-lines. Sensitivity and specificity for the presence of bilateral B-lines and any B-lines were calculated based on discharge diagnosis. Clips archived to the ultrasound units were reviewed and paramedic interpretations were compared to expert sonologist interpretations.

RESULTS: A total of 63 paramedics completed both didactic and hands-on training, and 22 performed ultrasounds in the field. There were 65 patients with B-line findings recorded and a discharge diagnosis for analysis. The presence of bilateral B-lines for diagnosis of CHF yielded a sensitivity of 80.0% (95% confidence interval [CI], 51.4-94.7%) and specificity of 72.0% (95% CI, 57.3-83.3), while presence of any B-lines was 93.3% sensitive (95% CI, 66.0-99.7%), and 50% specific (95% CI, 35.7-64.2%) for CHF. Paramedics archived 117 ultrasound clips of which 63% were determined to be adequate for interpretation. Comparison of paramedic and expert sonologist interpretation of images showed good inter-rater agreement for detection of any B-lines (k = 0.60; 95% CI, 0.36-0.84).

CONCLUSION: This observational pilot study suggests that prehospital lung ultrasound for B-lines may aid in identifying or excluding CHF as a cause of dyspnea. The presence of bilateral B-lines as determined by paramedics is reasonably sensitive and specific for the diagnosis of CHF and pulmonary edema, while the absence of B lines is likely to exclude significant decompensated heart failure. The study was limited by being a convenience sample and highlighted some of the difficulties related to prehospital research. Larger funded trials will be needed to provide more definitive data.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app