We have located links that may give you full text access.
Standardized, musculoskeletal ultrasonographic reference values for healthy Korean adults.
Korean Journal of Internal Medicine 2018 May 5
Background/Aims: To define standard reference values for musculoskeletal ultrasonography (MSUS) in Korea.
Methods: A total of 251 healthy adults were recruited for this study. Ultrasonography was performed by experienced rheumatologists who had undergone four appropriate training programs in Korea. A General Electric LOGIQ electronic ultrasound device fitted with a 12 MHz linear transducer was employed. Mean values ± standard deviations (SDs) were defined as standard reference values. Intraclass correlation coefficients was employed to evaluate the extent of inter- and intraobserver agreement when MSUS measurements were made.
Results: The 251 study participants included 122 males. Mean subject age was 28.6 years. The average bone-to-capsule distance of the right-side second and third metacarpophalangeal (MCP) joints were 0.68 and 0.72 mm respectively, and those of the left-side joints 0.62 and 0.68 mm. The cartilage thicknesses of the rightside second and third MCP joints were 0.55 and 0.55 mm, and those of the leftside joints were 0.55 and 0.56 mm, respectively. The bone-to-capsule distances of the right and left wrists were 0.80 and 0.82 mm. In 12.4% of participants (31/251), the erosion score of the humeral head was 1.71. In the right-side knee joint, mean cartilage thicknesses of the medial and lateral condyles were 1.86 and 2.03 mm in longitudinal scans. High overall interobserver agreement was evident after appropriate training that included instruction on standard MSUS methodology.
Conclusions: We defined standard reference values for MSUS in healthy Korean adults. The reliabilities of interobserver agreements were high after appropriate training program.
Methods: A total of 251 healthy adults were recruited for this study. Ultrasonography was performed by experienced rheumatologists who had undergone four appropriate training programs in Korea. A General Electric LOGIQ electronic ultrasound device fitted with a 12 MHz linear transducer was employed. Mean values ± standard deviations (SDs) were defined as standard reference values. Intraclass correlation coefficients was employed to evaluate the extent of inter- and intraobserver agreement when MSUS measurements were made.
Results: The 251 study participants included 122 males. Mean subject age was 28.6 years. The average bone-to-capsule distance of the right-side second and third metacarpophalangeal (MCP) joints were 0.68 and 0.72 mm respectively, and those of the left-side joints 0.62 and 0.68 mm. The cartilage thicknesses of the rightside second and third MCP joints were 0.55 and 0.55 mm, and those of the leftside joints were 0.55 and 0.56 mm, respectively. The bone-to-capsule distances of the right and left wrists were 0.80 and 0.82 mm. In 12.4% of participants (31/251), the erosion score of the humeral head was 1.71. In the right-side knee joint, mean cartilage thicknesses of the medial and lateral condyles were 1.86 and 2.03 mm in longitudinal scans. High overall interobserver agreement was evident after appropriate training that included instruction on standard MSUS methodology.
Conclusions: We defined standard reference values for MSUS in healthy Korean adults. The reliabilities of interobserver agreements were high after appropriate training program.
Full text links
Related Resources
Trending Papers
British Society of Gastroenterology guidelines for the management of hepatocellular carcinoma in adults.Gut 2024 April 17
Systemic lupus erythematosus.Lancet 2024 April 18
Should renin-angiotensin system inhibitors be held prior to major surgery?British Journal of Anaesthesia 2024 May
Ventilator Waveforms May Give Clues to Expiratory Muscle Activity.American Journal of Respiratory and Critical Care Medicine 2024 April 25
Acute Kidney Injury and Electrolyte Imbalances Caused by Dapagliflozin Short-Term Use.Pharmaceuticals 2024 March 27
Colorectal polypectomy and endoscopic mucosal resection: European Society of Gastrointestinal Endoscopy (ESGE) Guideline - Update 2024.Endoscopy 2024 April 27
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app