Pulmonary subsolid nodules: value of semi-automatic measurement in diagnostic accuracy, diagnostic reproducibility and nodule classification agreement.
European Radiology 2018 May
OBJECTIVES: We hypothesized that semi-automatic diameter measurements would improve the accuracy and reproducibility in discriminating preinvasive lesions and minimally invasive adenocarcinomas from invasive pulmonary adenocarcinomas appearing as subsolid nodules (SSNs) and increase the reproducibility in classifying SSNs.
METHODS: Two readers independently performed semi-automatic and manual measurements of the diameters of 102 SSNs and their solid portions. Diagnostic performance in predicting invasive adenocarcinoma based on diameters was tested using logistic regression analysis with subsequent receiver operating characteristic curves. Inter- and intrareader reproducibilities of diagnosis and SSN classification according to Fleischner's guidelines were investigated for each measurement method using Cohen's κ statistics.
RESULTS: Semi-automatic effective diameter measurements were superior to manual average diameters for the diagnosis of invasive adenocarcinoma (AUC, 0.905-0.923 for semi-automatic measurement and 0.833-0.864 for manual measurement; p<0.05). Reproducibility of diagnosis between the readers also improved with semi-automatic measurement (κ=0.924 for semi-automatic measurement and 0.690 for manual measurement, p=0.012). Inter-reader SSN classification reproducibility was significantly higher with semi-automatic measurement (κ=0.861 for semi-automatic measurement and 0.683 for manual measurement, p=0.022).
CONCLUSIONS: Semi-automatic effective diameter measurement offers an opportunity to improve diagnostic accuracy and reproducibility as well as the classification reproducibility of SSNs.
KEY POINTS: • Semi-automatic effective diameter measurement improves the diagnostic accuracy for pulmonary subsolid nodules. • Semi-automatic measurement increases the inter-reader agreement on the diagnosis for subsolid nodules. • Semi-automatic measurement augments the inter-reader reproducibility for the classification of subsolid nodules.
METHODS: Two readers independently performed semi-automatic and manual measurements of the diameters of 102 SSNs and their solid portions. Diagnostic performance in predicting invasive adenocarcinoma based on diameters was tested using logistic regression analysis with subsequent receiver operating characteristic curves. Inter- and intrareader reproducibilities of diagnosis and SSN classification according to Fleischner's guidelines were investigated for each measurement method using Cohen's κ statistics.
RESULTS: Semi-automatic effective diameter measurements were superior to manual average diameters for the diagnosis of invasive adenocarcinoma (AUC, 0.905-0.923 for semi-automatic measurement and 0.833-0.864 for manual measurement; p<0.05). Reproducibility of diagnosis between the readers also improved with semi-automatic measurement (κ=0.924 for semi-automatic measurement and 0.690 for manual measurement, p=0.012). Inter-reader SSN classification reproducibility was significantly higher with semi-automatic measurement (κ=0.861 for semi-automatic measurement and 0.683 for manual measurement, p=0.022).
CONCLUSIONS: Semi-automatic effective diameter measurement offers an opportunity to improve diagnostic accuracy and reproducibility as well as the classification reproducibility of SSNs.
KEY POINTS: • Semi-automatic effective diameter measurement improves the diagnostic accuracy for pulmonary subsolid nodules. • Semi-automatic measurement increases the inter-reader agreement on the diagnosis for subsolid nodules. • Semi-automatic measurement augments the inter-reader reproducibility for the classification of subsolid nodules.
Full text links
Related Resources
Trending Papers
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Prevention and treatment of ischaemic and haemorrhagic stroke in people with diabetes mellitus: a focus on glucose control and comorbidities.Diabetologia 2024 April 17
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Eosinophilic Esophagitis: Clinical Pearls for Primary Care Providers and Gastroenterologists.Mayo Clinic Proceedings 2024 April
Essential thrombocythaemia: A contemporary approach with new drugs on the horizon.British Journal of Haematology 2024 April 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app