We have located links that may give you full text access.
Use and Efficacy of I-Gel in Complicated Intubations in Newborn Infants: A Review of Case Reports in the Literature.
Current Pediatric Reviews 2024 April 30
INTRODUCTION: Current guidelines for neonatal resuscitation suggest the use of a laryngeal mask when ventilation with both facemask and endotracheal tube has failed in newborns weighing >2000 g or delivered ≥ 34 weeks of gestation age. Paediatric I-gel® is one of the latest supraglottic airway management devices suitable for children and newborns. I-gel® use was effective in guaranteeing adequate ventilation in patients with anatomic abnormalities in case of respiratory impairment or during surgical procedures after the induction of anaesthesia.
OBJECTIVE: The purpose of our review was to evaluate the use and efficacy of I-gel® in case of complicated intubations.
METHODS: In July 2023, two authors of this paper independently conducted searches of the MEDLINE, Web of Science, and Scopus databases without imposing any time constraints or other restrictions. Three case reports were included, each describing the use of I-gel® device in difficult intubations in newborns with anatomical abnormalities.
RESULTS: No difficulties were reported in the insertion of the device, which was placed even by inexperienced clinicians.
CONCLUSION: The data collected highlighted the possibility of using I-gel® not only as a rescue device after attempted and failed endotracheal placement but also as a first choice in selected patients. Studies on larger cohorts would be needed. Further research involving larger patient cohorts of multicentre NICUs is necessary to confirm the use of laryngeal masks in neonates weighing less than 2000 grams.
OBJECTIVE: The purpose of our review was to evaluate the use and efficacy of I-gel® in case of complicated intubations.
METHODS: In July 2023, two authors of this paper independently conducted searches of the MEDLINE, Web of Science, and Scopus databases without imposing any time constraints or other restrictions. Three case reports were included, each describing the use of I-gel® device in difficult intubations in newborns with anatomical abnormalities.
RESULTS: No difficulties were reported in the insertion of the device, which was placed even by inexperienced clinicians.
CONCLUSION: The data collected highlighted the possibility of using I-gel® not only as a rescue device after attempted and failed endotracheal placement but also as a first choice in selected patients. Studies on larger cohorts would be needed. Further research involving larger patient cohorts of multicentre NICUs is necessary to confirm the use of laryngeal masks in neonates weighing less than 2000 grams.
Full text links
Related Resources
Trending Papers
Guillain-Barré syndrome: History, pathogenesis, treatment, and future directions.European Journal of Neurology 2024 May 17
Contrast-induced acute kidney injury: a review of definition, pathogenesis, risk factors, prevention and treatment.BMC Nephrology 2024 April 23
Angiotensin Receptor Blocker-Neprilysin Inhibitor for Heart Failure with Reduced Ejection Fraction.Pharmacological Research : the Official Journal of the Italian Pharmacological Society 2024 May 12
The Therapy and Management of Heart Failure with Preserved Ejection Fraction: New Insights on Treatment.Cardiac Failure Review 2024
European Respiratory Society Clinical Practice Guideline on symptom management for adults with serious respiratory illness.European Respiratory Journal 2024 May 9
Axillary Surgery for Breast Cancer in 2024.Cancers 2024 April 24
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app