We have located links that may give you full text access.
Development of a method for the determination of sedatives in bovine and porcine urine and kidneys by liquid chromatography-tandem mass spectrometry.
Journal of Veterinary Research 2024 March
INTRODUCTION: Sedatives have been used for a long time as animal tranquillisers to prevent stress and weight loss during their transportation. The proper determination of these substances in food of animal origin is essential for consumer safety.
MATERIAL AND METHODS: A 1 g portion of pig or cow urine or homogenised kidney was mixed with acetonitrile, sodium chloride was added, and the solution was further mixed and then centrifuged. The supernatant was transferred to a new centrifuge tube with primary and secondary amine, octadecylsilane and ZrO2 , and mixed rapidly. The filtered solution was evaporated under a nitrogen stream. The residue was dissolved in 200 μL of acetonitrile, centrifuged with filters and then transferred to vials. Samples were analysed by high-performance liquid chromatography-tandem mass spectrometry.
RESULTS: The decision limit for confirmation was calculated at 2.5 μg kg-1 for all sedatives with relative standard deviation repeatability and reproducibility below 20%.
CONCLUSION: The validation results showed that this method meets the pertinent EU criteria for such methods and is suitable for sedative analysis in urine and kidney matrices.
MATERIAL AND METHODS: A 1 g portion of pig or cow urine or homogenised kidney was mixed with acetonitrile, sodium chloride was added, and the solution was further mixed and then centrifuged. The supernatant was transferred to a new centrifuge tube with primary and secondary amine, octadecylsilane and ZrO2 , and mixed rapidly. The filtered solution was evaporated under a nitrogen stream. The residue was dissolved in 200 μL of acetonitrile, centrifuged with filters and then transferred to vials. Samples were analysed by high-performance liquid chromatography-tandem mass spectrometry.
RESULTS: The decision limit for confirmation was calculated at 2.5 μg kg-1 for all sedatives with relative standard deviation repeatability and reproducibility below 20%.
CONCLUSION: The validation results showed that this method meets the pertinent EU criteria for such methods and is suitable for sedative analysis in urine and kidney matrices.
Full text links
Related Resources
Trending Papers
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Prevention and treatment of ischaemic and haemorrhagic stroke in people with diabetes mellitus: a focus on glucose control and comorbidities.Diabetologia 2024 April 17
British Society for Rheumatology guideline on management of adult and juvenile onset Sjögren disease.Rheumatology 2024 April 17
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Albumin: a comprehensive review and practical guideline for clinical use.European Journal of Clinical Pharmacology 2024 April 13
Eosinophilic Esophagitis: Clinical Pearls for Primary Care Providers and Gastroenterologists.Mayo Clinic Proceedings 2024 April
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app