Enhancing Quantitative Analysis of Xenobiotics in Blood Plasma through Cross-Matrix Calibration and Bayesian Hierarchical Modeling.

ACS Meas Sci Au 2024 Februrary 22
This study addresses the challenges of matrix effects and interspecies plasma protein binding (PPB) on measurement variability during method validation across diverse plasma types (human, rat, rabbit, and bovine). Accurate measurements of small molecules in plasma samples often require matrix-matched calibration approaches with the use of specific plasma types, which may have limited availability or affordability. To mitigate the costs associated with human plasma measurements, we explore in this work the potential of cross-matrix-matched calibration using Bayesian hierarchical modeling (BHM) to correct for matrix effects associated with PPB. We initially developed a targeted quantitative approach utilizing biocompatible solid-phase microextraction coupled with liquid chromatography-mass spectrometry for xenobiotic analysis in plasma. The method was evaluated for absolute matrix effects across human, bovine, rat, and rabbit plasma comparing pre- and postmatrix extraction standards. Absolute matrix effects from 96 to 108% for most analytes across plasma sources indicate that the biocompatibility of the extraction phase minimizes interference coextraction. However, the extent of PPB in different media can still affect the accuracy of the measurement when the extraction of small molecules is carried out via free concentration, as in the case of microextraction techniques. In fact, while matrix-matched calibration revealed high accuracy, cross-matrix calibration (e.g., using a calibration curve generated from bovine plasma) proved inadequate for precise measurements in human plasma. A BHM was used to calculate correction factors for each analyte within each plasma type, successfully mitigating the measurement bias resulting from diverse calibration curve types used to quantify human plasma samples. This work contributes to the development of cost-effective, efficient calibration strategies for biofluids. Leveraging easily accessible plasma sources, like bovine plasma, for method optimization and validation prior to analyzing costly plasma (e.g., human plasma) holds substantial advantages applicable to biomonitoring and pharmacokinetic studies.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app