We have located links that may give you full text access.
Characterization of blood-mimicking fluids for echocardiography imaging of ventricular septal defects.
PURPOSE: Ventricular septal defects (VSD) are congenital heart malformations and, in severe cases, they require complex interventions under echocardiography guidance. Heart phantoms can be helpful to train and to understand the complex hemodynamics of VSD. The goal of this study was to characterize the best blood mimicking fluids in such heart phantoms for modelling the hemodynamics of VSD patients using echocardiography.
METHODS: Four fluid compositions were considered. Distilled water was used as a baseline, while the other three fluids were developed based on physical properties of human blood, such as the viscosity and the refractive index. Three bi-ventricular heart phantoms of three different pediatric patients with complex VSD were designed from preoperative CT imaging. Custom molds were printed in 3-D and the anatomical structure was casted in polyvinyl alcohol cryogel. The VSD in each heart phantom were observed using echocardiography and color Doppler imaging was used for the hemodynamic study.
RESULTS: Heart phantoms with blood mimicking fluids of 30% glycerol and 27% glycerol, 10% sodium iodide were found to be anatomically realistic under echocardiography imaging. Hemodynamic parameters such as the pressure gradient and the volume of the shunt were characterized using color Doppler imaging.
CONCLUSION: Proper composition of blood mimicking fluids are important for improving the realism in echocardiographic heart phantoms and they contribute to better understand the complex hemodynamic of VSD under echocardiography.
METHODS: Four fluid compositions were considered. Distilled water was used as a baseline, while the other three fluids were developed based on physical properties of human blood, such as the viscosity and the refractive index. Three bi-ventricular heart phantoms of three different pediatric patients with complex VSD were designed from preoperative CT imaging. Custom molds were printed in 3-D and the anatomical structure was casted in polyvinyl alcohol cryogel. The VSD in each heart phantom were observed using echocardiography and color Doppler imaging was used for the hemodynamic study.
RESULTS: Heart phantoms with blood mimicking fluids of 30% glycerol and 27% glycerol, 10% sodium iodide were found to be anatomically realistic under echocardiography imaging. Hemodynamic parameters such as the pressure gradient and the volume of the shunt were characterized using color Doppler imaging.
CONCLUSION: Proper composition of blood mimicking fluids are important for improving the realism in echocardiographic heart phantoms and they contribute to better understand the complex hemodynamic of VSD under echocardiography.
Full text links
Related Resources
Trending Papers
Consensus Statement on Vitamin D Status Assessment and Supplementation: Whys, Whens, and Hows.Endocrine Reviews 2024 April 28
The Tricuspid Valve: A Review of Pathology, Imaging, and Current Treatment Options: A Scientific Statement From the American Heart Association.Circulation 2024 April 26
Intravenous infusion of dexmedetomidine during the surgery to prevent postoperative delirium and postoperative cognitive dysfunction undergoing non-cardiac surgery: a meta-analysis of randomized controlled trials.European Journal of Medical Research 2024 April 19
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Ventilator Waveforms May Give Clues to Expiratory Muscle Activity.American Journal of Respiratory and Critical Care Medicine 2024 April 25
Acute Kidney Injury and Electrolyte Imbalances Caused by Dapagliflozin Short-Term Use.Pharmaceuticals 2024 March 27
Systemic lupus erythematosus.Lancet 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app