We have located links that may give you full text access.
Continuous invasive hemodynamic monitoring using steerable guide catheter to optimize mitraclip transcatheter mitral valve repair: A multicenter, proof-of-concept study.
Journal of Interventional Cardiology 2018 August 31
OBJECTIVES: We report our multicenter experience on continuous hemodynamic monitoring using exclusively the steerable guide catheter (SGC) during MitraClip repair.
BACKGROUND: Left atrial pressure (LAP) and V-wave are useful to evaluate MitraClip repair but no simple method of continuous monitoring exists.
METHODS: From 11/2016 to 8/2017, 74 patients from four centers with symptomatic moderate-severe to severe mitral regurgitation (MR), underwent MitraClip NT repair with continuous hemodynamic monitoring via the SGC. Real-time LAP/V-wave changes were compared with transesophageal echocardiography (TEE). When mitral stenosis was suspected, transmitral gradients were verified by invasive hemodynamics. Clinical and echocardiographic outcomes were determined.
RESULTS: Mean age was 78 ± 10 years and STS score 9.1 ± 11.0%. Pathology included leaflet prolapse/flail (45%), restriction (35%), and mixed (20%). Number of clips averaged 1.7 ± 0.7 per case. There was a significant reduction in LAP (21 ± 10 to 15 ± 7 mmHg, P < 0.0001) and V-wave(37 ± 19 to 24 ± 10 mmHg, P < 0.0001) post MitraClip, but the decrease was less in patients with atrial fibrillation (P < 0.05). Transmitral gradient significantly increased from 2.0 ± 1.2 to 4.0 ± 1.7 mmHg (P < 0.0001). Paradoxical increases in LAP and V-wave despite MR reduction were observed in three cases requiring MitraClip repositioning or retrieval to avoid stenosis. Follow-up averaged 5.0 ± 2.9 months and was 100% complete. KCCQ improvement was significant and MR reduction to <1+ was 67% and <2+ was 93% at 30 days.
CONCLUSIONS: Continuous hemodynamic monitoring using the SGC complements TEE to assess and optimize MitraClip repair in real-time. Further validation is necessary but this feature may be part of future MitraClip and other transcatheter mitral repair systems.
BACKGROUND: Left atrial pressure (LAP) and V-wave are useful to evaluate MitraClip repair but no simple method of continuous monitoring exists.
METHODS: From 11/2016 to 8/2017, 74 patients from four centers with symptomatic moderate-severe to severe mitral regurgitation (MR), underwent MitraClip NT repair with continuous hemodynamic monitoring via the SGC. Real-time LAP/V-wave changes were compared with transesophageal echocardiography (TEE). When mitral stenosis was suspected, transmitral gradients were verified by invasive hemodynamics. Clinical and echocardiographic outcomes were determined.
RESULTS: Mean age was 78 ± 10 years and STS score 9.1 ± 11.0%. Pathology included leaflet prolapse/flail (45%), restriction (35%), and mixed (20%). Number of clips averaged 1.7 ± 0.7 per case. There was a significant reduction in LAP (21 ± 10 to 15 ± 7 mmHg, P < 0.0001) and V-wave(37 ± 19 to 24 ± 10 mmHg, P < 0.0001) post MitraClip, but the decrease was less in patients with atrial fibrillation (P < 0.05). Transmitral gradient significantly increased from 2.0 ± 1.2 to 4.0 ± 1.7 mmHg (P < 0.0001). Paradoxical increases in LAP and V-wave despite MR reduction were observed in three cases requiring MitraClip repositioning or retrieval to avoid stenosis. Follow-up averaged 5.0 ± 2.9 months and was 100% complete. KCCQ improvement was significant and MR reduction to <1+ was 67% and <2+ was 93% at 30 days.
CONCLUSIONS: Continuous hemodynamic monitoring using the SGC complements TEE to assess and optimize MitraClip repair in real-time. Further validation is necessary but this feature may be part of future MitraClip and other transcatheter mitral repair systems.
Full text links
Related Resources
Trending Papers
Consensus Statement on Vitamin D Status Assessment and Supplementation: Whys, Whens, and Hows.Endocrine Reviews 2024 April 28
The Tricuspid Valve: A Review of Pathology, Imaging, and Current Treatment Options: A Scientific Statement From the American Heart Association.Circulation 2024 April 26
Intravenous infusion of dexmedetomidine during the surgery to prevent postoperative delirium and postoperative cognitive dysfunction undergoing non-cardiac surgery: a meta-analysis of randomized controlled trials.European Journal of Medical Research 2024 April 19
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Ventilator Waveforms May Give Clues to Expiratory Muscle Activity.American Journal of Respiratory and Critical Care Medicine 2024 April 25
Acute Kidney Injury and Electrolyte Imbalances Caused by Dapagliflozin Short-Term Use.Pharmaceuticals 2024 March 27
Systemic lupus erythematosus.Lancet 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app