OBJECTIVE: Effective and comfortable debridement is an important part of managing complex wounds. This user test evaluated a monofilament-fibre pad (with handle) (Debrisoft Lolly, Lohmann & Rauscher GmbH & Co. KG) in the debridement of various hard-to-reach wounds.
METHOD: The multicentre, international user test was performed by experienced physicians and nurses in Germany and the UK, who used the monofilament-fibre pad in their clinical practice. After debridement, using the monofilament-fibre pad, the clinicians completed an evaluation questionnaire. The assessment comprised of performance, usability, tolerability, safety and suitability of the device for debridement, comparing it with standard methods used in the clinicians' centres.
RESULTS: A total of 23 clinicians in 20 centres each treated between six and 10 patients with the monofilament-fibre pad (a total of 155 wounds of different aetiologies). Most participating patients had deep wounds (n=63 (41%)) or cavity (n=31 (20%)) wounds. When compared with the standard debridement method used at the centres, the tested device was scored as 'easier' or 'equally easy' to use in all cases. When comparing the standard debridement procedure with the monofilament-fibre pad, debridement duration was reported as equal to or shorter than the standard method in 90% of cases when using the monofilament-fibre pad. Debridement efficacy was scored by the clinician as 'better' or 'equal' for the monofilament-fibre pad in 67% of cases. Overall, patients reported that the study device was comfortable.
CONCLUSION: The monofilament-fibre pad effectively, easily and safely removed slough and debris from wounds of various aetiologies and was effective in wounds of different shapes, such as in cavity wounds and those in hard-to-reach locations.
METHOD: The multicentre, international user test was performed by experienced physicians and nurses in Germany and the UK, who used the monofilament-fibre pad in their clinical practice. After debridement, using the monofilament-fibre pad, the clinicians completed an evaluation questionnaire. The assessment comprised of performance, usability, tolerability, safety and suitability of the device for debridement, comparing it with standard methods used in the clinicians' centres.
RESULTS: A total of 23 clinicians in 20 centres each treated between six and 10 patients with the monofilament-fibre pad (a total of 155 wounds of different aetiologies). Most participating patients had deep wounds (n=63 (41%)) or cavity (n=31 (20%)) wounds. When compared with the standard debridement method used at the centres, the tested device was scored as 'easier' or 'equally easy' to use in all cases. When comparing the standard debridement procedure with the monofilament-fibre pad, debridement duration was reported as equal to or shorter than the standard method in 90% of cases when using the monofilament-fibre pad. Debridement efficacy was scored by the clinician as 'better' or 'equal' for the monofilament-fibre pad in 67% of cases. Overall, patients reported that the study device was comfortable.
CONCLUSION: The monofilament-fibre pad effectively, easily and safely removed slough and debris from wounds of various aetiologies and was effective in wounds of different shapes, such as in cavity wounds and those in hard-to-reach locations.
Full text links
Related Resources
Trending Papers
British Society of Gastroenterology guidelines for the management of hepatocellular carcinoma in adults.Gut 2024 April 17
Systemic lupus erythematosus.Lancet 2024 April 18
Should renin-angiotensin system inhibitors be held prior to major surgery?British Journal of Anaesthesia 2024 May
Ventilator Waveforms May Give Clues to Expiratory Muscle Activity.American Journal of Respiratory and Critical Care Medicine 2024 April 25
Acute Kidney Injury and Electrolyte Imbalances Caused by Dapagliflozin Short-Term Use.Pharmaceuticals 2024 March 27
Colorectal polypectomy and endoscopic mucosal resection: European Society of Gastrointestinal Endoscopy (ESGE) Guideline - Update 2024.Endoscopy 2024 April 27
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app