Simethicone improves bowel cleansing with low-volume polyethylene glycol: a multicenter randomized trial.
Endoscopy 2018 April
BACKGROUND AND STUDY AIMS: For bowel preparation, using a reduced volume of polyethylene glycol (PEG) solution without influencing its effectiveness would be preferable. While simethicone shows great potential as an adjunctive agent, data on its use are limited. We aimed to clarify whether simethicone added to low-volume PEG solution improved bowel cleansing. PATIENTS AND METHODS : Consecutive adult patients registered for colonoscopy were recruited from seven medical centers in South China between 15 April and 15 July 2015 and prospectively randomized into two groups: 2 L PEG (conventional group) and 2 L PEG plus simethicone (simethicone group). The primary endpoint was the effectiveness of bowel cleansing according to the Boston Bowel Preparation Scale (BBPS). Secondary endpoints included cecal intubation time, adenoma detection rate (ADR), patient safety and compliance, and adverse events. RESULTS : We included 290 and 289 patients in the conventional and simethicone groups, respectively, for analysis. The proportion with acceptable bowel cleansing (BBPS ≥ 6) was significantly higher in the simethicone group than in the conventional group (88.2 % vs. 76.6 %; P < 0.001). The mean (SD) BBPS score was significantly lower in the conventional group (6.5 [1.8] vs. 7.3 [1.7]; P < 0.001), as was the bubble score (2.5 [0.7] vs. 2.8 [0.5]; P < 0.001). The average cecal intubation time was significantly shorter in the simethicone group (6.3 [3.1] vs. 7.5 [5.1] minutes; P < 0.001). The ADR in the right colon was higher in the simethicone group than in the conventional group (16.6 % vs. 10.3 %; P = 0.03). Safety and compliance, including the taste, smell, and dosage of PEG, were similar for both groups.
CONCLUSIONS: Simethicone added to low-volume PEG solution improves bowel-cleansing efficacy, with similar safety and compliance, shorter cecal intubation time, and higher ADR.
CONCLUSIONS: Simethicone added to low-volume PEG solution improves bowel-cleansing efficacy, with similar safety and compliance, shorter cecal intubation time, and higher ADR.
Full text links
Related Resources
Trending Papers
British Society of Gastroenterology guidelines for the management of hepatocellular carcinoma in adults.Gut 2024 April 17
Systemic lupus erythematosus.Lancet 2024 April 18
Should renin-angiotensin system inhibitors be held prior to major surgery?British Journal of Anaesthesia 2024 May
Ventilator Waveforms May Give Clues to Expiratory Muscle Activity.American Journal of Respiratory and Critical Care Medicine 2024 April 25
Acute Kidney Injury and Electrolyte Imbalances Caused by Dapagliflozin Short-Term Use.Pharmaceuticals 2024 March 27
Colorectal polypectomy and endoscopic mucosal resection: European Society of Gastrointestinal Endoscopy (ESGE) Guideline - Update 2024.Endoscopy 2024 April 27
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app