[Application of self made guidance for difficult gastric tube placement in patients with artificial airway].

OBJECTIVE: To use evidence-based nursing on patients with artificial airway to the practice of stomach tube, and to evaluate the self made guidance for difficult gastric tube placement in patients with artificial airway.

METHODS: Forty patients with artificial airway and were difficult to put the tube, and admitted to Department of Critical Care Medicine of Harrison International Peace Hospital Affiliated to Hebei Medical University from April to December in 2016 were enrolled as observation group. Through the evidence-based nursing strategy, the related literatures at home and abroad were collected to search clinical evidence and formulate and implement the nursing program, the gastric tube was inserted into the stomach tube under the direct vision of the laryngoscope. Thirty-six patients of difficult gastric tube placement with artificial airway straightly under the direct vision of the laryngoscope from August 2015 to March 2016 were retrospectively analyzed as the control group. The success rate of first catheterization, indwelling time, throat edema and bleeding of pharyngeal mucosa were compared between the two groups.

RESULTS: All patients were enrolled in the final analysis. In the control group, 28 patients were successfully placed once, while 8 failed. Only 1 patient in observation group failed to catheterize, and successful placed after symptomatic treatment, the one-time success rate of catheter was significantly higher than that of control group (97.5% vs. 77.8%), and catheter time was significantly shortened (minutes: 4.8±1.2 vs. 5.1±1.0), the difference was statistically significant (both P < 0.05). There were 2 patients with laryngeal edema in the control group and 4 patients of pharyngeal mucosal hemorrhage. In the observation group, there was no laryngeal edema and laryngeal edema occurred in the patients with laryngoscopy, and only 1 patient had a hemorrhage of pharyngeal mucosa.

CONCLUSIONS: Using self made guiding device can effectively insert the difficult gastric tube in patients with artificial airway, and increase the one-time success rate of intubation, shorten the catheter time, and have a trend in reduce complication as compared with traditional gastric tube placement.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app