[Use of gum elastic bougie for tracheal intubation: comparison of different tracheal tubes].
Masui. the Japanese Journal of Anesthesiology 2008 August
BACKGROUND: Gum elastic bougie (GEB) is one of the most useful devices for patients whose tracheas are difficult to intubate during anesthetic induction. But no previous study has evaluated the effects of the types of the tracheal tube. We hypothesized that wire-reinforced tracheal tubes were superior to standard tracheal tubes in the success rate of tracheal intubation when using GEB. We compared these two different types of tracheal tubes in using GEB.
METHODS: Forty patients were subjected and randomly allocated into two groups; patients intubated with standard tracheal tubes (Group , n = 20) and those with wire-reinforced tracheal tubes (Group S, n = 20). Measured variables were intubation time defined as elapsed time from mouth opening to removal of GEB from tracheal tube, heart rate (HR), and systolic blood pressure(SBP). We also compared trial times of intubation and pharyngeal or laryngeal bleeding as a minor side effect.
RESULTS: Trachea was successfully intubated in the frist attempt in 37 patients (92.5%), and the rest of the patients were all intubated at second trial. Intubation times of Group P and Group S were 41.5 +/- 13.9s and 41.3 +/- 11.1s, respectively. There were no significant differences in HR and SBP between the groups.
CONCLUSIONS: The type of tracheal tube would not affect the success rate and time of intubation when using gum elastic bougie.
METHODS: Forty patients were subjected and randomly allocated into two groups; patients intubated with standard tracheal tubes (Group , n = 20) and those with wire-reinforced tracheal tubes (Group S, n = 20). Measured variables were intubation time defined as elapsed time from mouth opening to removal of GEB from tracheal tube, heart rate (HR), and systolic blood pressure(SBP). We also compared trial times of intubation and pharyngeal or laryngeal bleeding as a minor side effect.
RESULTS: Trachea was successfully intubated in the frist attempt in 37 patients (92.5%), and the rest of the patients were all intubated at second trial. Intubation times of Group P and Group S were 41.5 +/- 13.9s and 41.3 +/- 11.1s, respectively. There were no significant differences in HR and SBP between the groups.
CONCLUSIONS: The type of tracheal tube would not affect the success rate and time of intubation when using gum elastic bougie.
Full text links
Related Resources
Trending Papers
British Society of Gastroenterology guidelines for the management of hepatocellular carcinoma in adults.Gut 2024 April 17
Systemic lupus erythematosus.Lancet 2024 April 18
Should renin-angiotensin system inhibitors be held prior to major surgery?British Journal of Anaesthesia 2024 May
Ventilator Waveforms May Give Clues to Expiratory Muscle Activity.American Journal of Respiratory and Critical Care Medicine 2024 April 25
Acute Kidney Injury and Electrolyte Imbalances Caused by Dapagliflozin Short-Term Use.Pharmaceuticals 2024 March 27
Colorectal polypectomy and endoscopic mucosal resection: European Society of Gastrointestinal Endoscopy (ESGE) Guideline - Update 2024.Endoscopy 2024 April 27
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app