United Reference Method for three-dimensional treatment evaluation.

Progress in Orthodontics 2018 December 4
BACKGROUND: Reproducible and descriptive Three-dimensional treatment evaluation can enhance future treatment based on realistic results. So, the purpose of this study was to describe a new method for three-dimensional treatment evaluation showing how to use fully-automated craniofacial superimposition of CBCT records combined with reference system to obtain descriptive and comparable results. This new method was named United Reference Method (URM).

METHODS: URM is a combination of automated 3D superimposition on anterior cranial base surface anatomy and measurements based on reference system. It was developed to show how to use fully-automated superimposition to obtain descriptive numerical comparable values. The method is based on: one main reference system for both superimposed CBCT records, semi-automation to increase accuracy, all measurements are projections and auxiliary references to aid in landmarks identification and measurements. The method steps can be described following a four-step approach: (1) Superimposition performed through a fully automated, voxel-wise, rigid registration considering only cranial base as a stable structure; (2) Identification of reference landmarks once on the superimposed records for corrected Frankfort Horizontal plane (C-FH) construction and a new semi-automated constructed Sella point to correct Orbital asymmetry; (3) Head orientation of superimposed CBCT images based on the C-FH; (4) Identification of landmarks affected by treatment with the aid of auxiliary reference planes. Evaluation of linear or angular changes derived by projection of same pre- and post-treatment landmarks on the C-FH. Pre- and post-expansion CBCT scans of 20 unilateral cleft lip and palate patients were used to calculate intra and inter-rater reliability. (X, Y and Z) coordinates, mean, standard deviation (SD) and Intra-class Correlation Coefficient (ICC) were calculated.

RESULTS: The proposed coordinates for C-FH construction showed ICC ≥ 0.998 and SD ranging from 0.064 to 0.242 mm. On the other hand, excluded coordinates due to expected natural craniofacial asymmetry had the lowest reliability ICC ≥0.742 and SD dramatically increased up to 1.112 mm.

CONCLUSION: URM showed adequate reliability so it can be used to produce three-dimensional descriptive data of craniofacial structural changes.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app