TRANSCATHETER AORTIC VALVE REPLACEMENT WITH THE NAVITOR SYSTEM: REAL-WORLD UNITED KINGDOM EXPERIENCE.
American Journal of Cardiology 2024 April 30
BACKGROUND: The Navitor (THV) is the latest iteration of the Portico self-expanding valve system. Early prospective studies have shown promising outcomes, however there is a lack of complementary 'real-world' data.
AIMS: To assess early safety and efficacy outcomes of the Navitor Transcatheter Heart Valve (THV) using registry data from six high-volume UK TAVR centers.
METHODS: Demographic, procedural and in-hospital outcome data were retrieved from six UK centers. The primary safety end-point was 30-day mortality. Primary efficacy end-points were procedural success, mean aortic gradient, and ≥moderate paravalvular leak (PVL). Secondary endpoints included rates of new pacemaker implantation (PPM), stroke and vascular injury.
RESULTS: 574 patients (Mean age 83.4 years; 54.5% female) underwent Navitor TAVR between January 2020 and May 2023. The 30-day mortality in this patient cohort was 1.6%. Procedural success was 98.1%, mean echo-derived gradient post-TAVR was 7.7±4.8mmHg (95% CI [7.2, 8.3], p<0.001) and 5.1% of patients had ≥moderate PVL (p̂=0.051, 95% CI [0.035, 0.073, p<0.001). New PPM to discharge was required in 11% (p̂ =0.119, 95% CI [0.088, 0.158], p<0.001), stroke occurred in 1.2% of patients (p̂= 0.017, 95% CI [0.006, 0.036], p<0.001) and significant vascular injury in 1.6% (p̂= 0.014, 95% CI [0.005, 0.032], p<0.001).
CONCLUSION: Early procedural outcomes with Navitor TAVR compare favorably to new generation THVs. Procedural success was high with a low incidence of complications.
AIMS: To assess early safety and efficacy outcomes of the Navitor Transcatheter Heart Valve (THV) using registry data from six high-volume UK TAVR centers.
METHODS: Demographic, procedural and in-hospital outcome data were retrieved from six UK centers. The primary safety end-point was 30-day mortality. Primary efficacy end-points were procedural success, mean aortic gradient, and ≥moderate paravalvular leak (PVL). Secondary endpoints included rates of new pacemaker implantation (PPM), stroke and vascular injury.
RESULTS: 574 patients (Mean age 83.4 years; 54.5% female) underwent Navitor TAVR between January 2020 and May 2023. The 30-day mortality in this patient cohort was 1.6%. Procedural success was 98.1%, mean echo-derived gradient post-TAVR was 7.7±4.8mmHg (95% CI [7.2, 8.3], p<0.001) and 5.1% of patients had ≥moderate PVL (p̂=0.051, 95% CI [0.035, 0.073, p<0.001). New PPM to discharge was required in 11% (p̂ =0.119, 95% CI [0.088, 0.158], p<0.001), stroke occurred in 1.2% of patients (p̂= 0.017, 95% CI [0.006, 0.036], p<0.001) and significant vascular injury in 1.6% (p̂= 0.014, 95% CI [0.005, 0.032], p<0.001).
CONCLUSION: Early procedural outcomes with Navitor TAVR compare favorably to new generation THVs. Procedural success was high with a low incidence of complications.
Full text links
Related Resources
Trending Papers
Obesity pharmacotherapy in older adults: a narrative review of evidence.International Journal of Obesity 2024 May 7
SGLT2 Inhibitors in Kidney Diseases-A Narrative Review.International Journal of Molecular Sciences 2024 May 2
Use of Intravenous Albumin: A Guideline from the International Collaboration for Transfusion Medicine Guidelines.Chest 2024 March 5
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app