Fabrication of paper-based analytical devices using stencil-printed glass varnish barriers for colorimetric detection of salivary α-amylase.

BACKGROUND: Developing disposable paper-based devices has positively impacted analytical science, particularly in developing countries. Some benefits of those devices include their versatility, affordability, environmentally friendly, and the possibility of being integrated with portable electrochemical or colorimetric detectors. Paper-based analytical devices (PADs) comprising circular zones and microfluidic networks have been successfully employed in the analytical chemistry reign. However, the combination of the stencil-printing method and alternative binder has not been satisfactorily explored for fabricating colorimetric paper devices.

RESULTS: We developed PADs exploring the stencil printing approach and glass varnish as the hydrophobic chemical agent. As a proof-of-concept, the colorimetric assay of salivary α-amylase (sAA) was performed in saliva samples. Through the scanning electron microscopy measurements, it was possible to indicate satisfactory definitions between native fibers and barrier, and that the measured values for the channel width revealed suitable fidelity (R2  = 0.99) with the nominal widths (ranging from 400 to 5000 μm). The proposed hydrophobic barrier exhibited excellent chemical resistance. The analytical applicability for detecting sAA revealed linear behavior in the range from 2 to 12 U mL-1  (R2  = 0.99), limit of detection of 0.75 U mL-1 , reproducibility (RSD ≤2.4%), recovery experiments ranged from 89 to 108% and AGREE response (0.86). In addition, the colorimetric analysis of sAA in four different saliva samples demonstrated levels ranging from 202 to 2080 U mL-1 , which enabled monitoring the absence and presence of periodontitis.

SIGNIFICANCE: This report has presented the first use of a self-adhesive mask and glass varnish for creating circular zones and microfluidic architectures on paper without using thermic or UV curing treatments. Also, the proposed analytical methodology for detecting sAA exhibited suitable ecological impact considering the AGREE tool. We believe the proposed fabrication of paper devices emerges as a novel, simple, high-fidelity microfluidic channel and portable analytical approach for colorimetric sensing.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app