Add like
Add dislike
Add to saved papers

Adding Electroanatomical Mapping to Cryoballoon Pulmonary Vein Isolation Improves 1-Year Clinical Outcome and Durability of Pulmonary Vein Isolation: A Propensity Score-Matched Analysis.

Background: Adding electroanatomical left atrial (LA) voltage mapping to cryoballoon ablation (CBA) improves validation of acute pulmonary vein isolation (PVI). Aims: To determine whether the addition of mapping can improve outcome and PVI durability. Methods: One-year outcome and PV reconnection (PVR) rate at first repeat ablation were studied in 400 AF patients in a propensity-matched analysis (age, AF type, CHA2 DS2 -VASc score) between Achieve catheter-guided CBA with additional EnSite LA voltage maps performed pre- and post-CBA (mapping group; N = 200) and CT- and Achieve catheter-guided CBA (control group; N = 200). Clinical success was defined as freedom of documented AF or atrial tachycardia (AT) > 30 s. PV reconnection patterns were characterized in repeat ablations. Results: At 1 year, 77 (19.25%) patients had recurrence of AF/AT, significantly lower than in the mapping group: 21 (10.5%) vs. 56 (28%), p < 0.001. Procedure time was shorter (72.2 ± 25.4 vs. 78.2 ± 29.3 min, p = 0.034) and radiation exposure lower (4465.0 ± 3454.6 Gy.cm2 vs. 5940.5 ± 4290.5 Gy.cm2 , p = 0.037). Use of mapping was protective towards AF/AT recurrence (HR = 0.348; 95% CI 0.210-0.579; p < 0.001), independent of persistent AF type (HR = 1.723; 95% CI 1.034-2.872; p = 0.037), and LA diameter (HR = 1.055; 95% CI 1.015-1.096; p = 0.006). At repeat ablation (N = 90), persistent complete PVI was seen in 14/20 (70.0%) versus 23/70 (32.9%) in the mapping and conventional group, respectively ( p = 0.03). Reconnection rate of the right inferior PV was lower with mapping (10.0% vs. 34,3%, p = 0.035). Conclusions: Adding electroanatomical LA voltage mapping to CBA improves 1-year clinical outcome and lowers both procedure time and radiation exposure. At repeat, use of mapping increases complete persistent PVI mainly by improving PVI durability of the RIPV.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app