Dosimetric comparison of 3DCRT and IMRT in radical chemoradiotherapy of squamous cell carcinoma esophagus.

BACKGROUND: Radical chemoradiation is the standard of treatment for locally advanced squamous cell carcinoma of esophagus and for patients with operable disease, but who are medically unfit or unwilling for surgery. As the esophagus is a central organ, the planning target volume (PTV) is central, lies close to the spinal cord and heart, and is surrounded by the lung, which is a radiosensitive organ. Irradiation of these critical structures is reduced by the use of three-dimensional conformal radiation therapy (3DCRT). Intensity-modulated radiation therapy (IMRT) has the potential to improve the uniformity of dose distribution to the tumor and reduce the dose received by surrounding normal tissues.

AIM AND OBJECTIVES: 1. To compare the dose distribution, conformity, and homogeneity indices in radical radiotherapy of squamous cell carcinoma of esophagus using 3DCRT and IMRT techniques 2. To compare the doses received by critical structures such as heart, lung, spinal cord, and liver.

MATERIALS AND METHODS: All cases of squamous cell carcinoma esophagus treated with radical chemoradiation to a dose of 50 Gy in 25 fractions using 3DCRT technique from January 2018 to July 2019 were included. IMRT plans were generated for these cases.The parameters that represent dose distribution to the target volume and the dose received by the organs at risk were obtained from the dose-volume histogram. The difference in the mean values of the parameters between the two techniques was calculated. The statistical significance of the difference was determined using Student's t-test and Wilcoxon signed-rank test.

RESULTS: The volume of PTV receiving 105% and 107% of prescribed dose was significantly lower with IMRT (3.540% and 0.008%, respectively) compared to 3DCRT (7.654% and 0.623%). The homogeneity index was better with IMRT (0.088 vs. 0.107) than 3DCRT. Conformity index was found to be better with IMRT (1.149 vs. 1.573). Mean heart dose (18.216 vs. 24.591 Gy) and the volume of heart receiving 30 Gy were reduced with IMRT. The volume of lung receiving 20 Gy and the volume receiving 5 Gy were not significantly different between 3DCRT and IMRT. Maximum dose to spinal cord was similar with 3DCRT and IMRT.

CONCLUSIONS: IMRT avoids areas of excessive irradiation within the PTV. IMRT improves dose conformity to the target volume and homogeneity of dose distribution within the PTV. The cardiac dose is significantly reduced with IMRT. The mean lung dose remains similar to 3DCRT. There is no significant increase in the volume of lung receiving low-dose radiation with IMRT.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app