Add like
Add dislike
Add to saved papers

Efficacy and safety of drug-coated balloon for de novo lesions of large coronary arteries: Systematic review and meta-analysis of randomized controlled trials.

Heliyon 2024 Februrary 16
BACKGROUND: Drug-coated balloon (DCB) is a novel approach to avoiding stent-related complications and has proven effective for the treatment of in-stent restenosis (ISR) and small vessels. However, its role in the treatment of de novo lesions in large vessels is less settled.

AIMS: To estimate the efficacy and safety of drug-coated balloon versus stent in the treatment of de novo lesions in large coronary arteries.

METHODS: We searched the literature until April 2023. We judged the safety of DCB based on major adverse cardiovascular events (MACEs), cardiac death, all-cause mortality, non-fatal myocardial infarction, target lesion revascularization (TLR), and bleeding event; and efficacy according to late lumen loss (LLL), minimum lumen diameter (MLD). We conducted subgroup analyses according to stent type and whether urgent PCI was required.

RESULTS: A total of 10 RCTs were included. Overall, LLL (mean difference (MD) = -0.19, 95 % confidence interval (CI): -0.32 to -0.06, P = 0.003) was lower in the DCB group than in the Stent arm. This effect was consistent in subgroup analysis regardless of stent type and disease type. In terms of safety indicators, there were no significant differences between DCB and stent. The subgroup analyses found that safety indicators showed no significant differences between DCB and drug-eluting stent (DES), but TLR was lower in the DCB than in the bare metal stent (BMS). Moreover, in ST-elevation myocardial infarction (STEMI), safety indicators and LLL showed no significant differences between DCB and DES, but MLD in the DCB was smaller. While in patients with excluded STEMI, MACE and TLR was lower in the DCB compared with the overall stent.

CONCLUSIONS: DCB could be a promising alternative for treating de novo lesions in large coronary arteries with satisfactory efficacy and low risk, superior to BMS and not inferior to DES, with a trend toward lower late lumen loss.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app