OBJECTIVE: The creation of an arteriovenous fistula (AVF) is considered the most effective hemodialysis (HD) vascular access. For patients who are not suitable for AVF, arteriovenous grafts (AVGs) are the best access option for chronic HD. However, conventional AVGs are prone to intimal hyperplasia, stenosis, thrombosis, and infection. Xeltis has developed an AVG as a potential alternative to currently available AVGs based on the concept of endogenous tissue restoration. The results of the first 6-month follow-up are presented here.
METHODS: The aXess first-in-human (FIH) study [NCT04898153] is a prospective, single-arm, multicenter feasibility study that evaluates the early safety and performance of the aXess Hemodialysis Graft. A total of 20 patients with end-stage renal disease were enrolled across six European investigational sites.
RESULTS: At 6-months follow-up, all grafts were patent with primary and secondary patency rates were 80% and 100%, respectively. Three patients required a re-intervention to maintain graft patency, while one re-intervention was required to restore patency. One graft thrombosis and zero infections were reported.
CONCLUSION: The expected advantages of the novel aXess Hemodialysis Graft over conventional AVGs would be evaluated by the analysis on long-term safety and effectiveness during the 5-year follow-up of the currently ongoing trial.
METHODS: The aXess first-in-human (FIH) study [NCT04898153] is a prospective, single-arm, multicenter feasibility study that evaluates the early safety and performance of the aXess Hemodialysis Graft. A total of 20 patients with end-stage renal disease were enrolled across six European investigational sites.
RESULTS: At 6-months follow-up, all grafts were patent with primary and secondary patency rates were 80% and 100%, respectively. Three patients required a re-intervention to maintain graft patency, while one re-intervention was required to restore patency. One graft thrombosis and zero infections were reported.
CONCLUSION: The expected advantages of the novel aXess Hemodialysis Graft over conventional AVGs would be evaluated by the analysis on long-term safety and effectiveness during the 5-year follow-up of the currently ongoing trial.
Full text links
Related Resources
Trending Papers
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
British Society for Rheumatology guideline on management of adult and juvenile onset Sjögren disease.Rheumatology 2024 April 17
Albumin: a comprehensive review and practical guideline for clinical use.European Journal of Clinical Pharmacology 2024 April 13
Renin-Angiotensin-Aldosterone System: From History to Practice of a Secular Topic.International Journal of Molecular Sciences 2024 April 5
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app