We have located links that may give you full text access.
Echocardiographic characteristics in neonates with septic shock.
European Journal of Pediatrics 2024 January 27
Clinical parameters used for hemodynamic assessment and titration of vasopressor therapy in neonates with septic shock have several limitations. Functional echocardiography is an emerging tool for bedside assessment of cardiac function and may be useful for diagnosis of shock and assessing the response to therapy. Data regarding echocardiographic parameters in neonates with shock is lacking. This prospective observational study was conducted in a Level III NICU with the primary objective of comparing echocardiographic characteristics of neonates with septic shock at diagnosis, following fluid boluses, and after maximum inotropic support [A1]. Additionally, we compared these characteristics with those of healthy stable neonates who were gestation and postnatal age-matched. A total of 36 neonates with septic shock and 30 gestation and postnatal age-matched controls were enrolled. The mean (SD) gestation and birth weight of neonates with septic shock were 30.6 (4.0) weeks and 1538 (728) g, respectively. Gram-negative bacilli constituted 78.9% of all isolates. At presentation, there was no significant difference between neonates with shock and controls in terms of ventricular outputs, shortening fraction, ratio of early to late diastolic trans-mitral flow velocity, and myocardial performance indices. The distensibility index of inferior vena cava was higher in neonates with shock compared to controls, (17% vs 10%, (p < 0.01)). Left ventricular output was 209 (92) and 227 (102) ml/kg/min (p = 0.53) and right ventricular output was 427 (203) and 459 (227) ml/kg/min, (p = 0.03), respectively, before and after inotropic therapy. Conclusion: Echocardiographic parameters may not differentiate neonates with septic shock from hemodynamically stable neonates. Neonates with shock associated with predominantly gram-negative sepsis are not able to augment cardiac functions, either at the onset or after administration of inotropes. Trial registration: (CTRI/2017/12/010766). What is known: • For neonates with shock, echocardiography is becoming increasingly popular as an objective method of evaluating hemodynamics. • In healthy preterm neonate, cardiac output has been known to increase in response to altered hemodynamics during states of increased oxygen demand. What is new: • In the setting of septic shock induced by gram-negative organisms, echocardiographic parameters are less likely to assist in the assessment of the response to vasoactive agents. Cytokines, induced by gram-negative organisms, may alter adrenoreceptors in myocardium and vasculature.
Full text links
Related Resources
Trending Papers
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
British Society for Rheumatology guideline on management of adult and juvenile onset Sjögren disease.Rheumatology 2024 April 17
Albumin: a comprehensive review and practical guideline for clinical use.European Journal of Clinical Pharmacology 2024 April 13
Renin-Angiotensin-Aldosterone System: From History to Practice of a Secular Topic.International Journal of Molecular Sciences 2024 April 5
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app