Reconstructive interpolation for pulse wave estimation to improve local PWV measurement of carotid artery.
Medical & Biological Engineering & Computing 2024 January 23
Ultrasonic transit time (TT)-based local pulse wave velocity (PWV) measurement is defined as the distance between two beam positions on a segment of common carotid artery (CCA) divided by the TT in the pulse wave propagation. However, the arterial wall motions (AWMs) estimated from ultrasonic radio frequency (RF) signals with a limited number of frames using the motion tracking are typically discrete. In this work, we develop a method involving motion tracking combined with reconstructive interpolation (MTRI) to reduce the quantification errors in the estimated PWs, and thereby improve the accuracy of the TT-based local PWV measurement for CCA. For each beam position, normalized cross-correlation functions (NCCFs) between the reference (the first frame) and comparison (the remaining frames) RF signals are calculated. Thereafter, the reconstructive interpolation is performed in the neighborhood of the NCCFs' peak to identify the interpolation-deduced peak locations, which are more exact than the original ones. According to which, the improved AWMs are obtained to calculate their TT along a segment of the CCA. Finally, the local PWV is measured by applying a linear regression fit to the time-distance result. In ultrasound simulations based on the pulse wave propagation models of young, middle-aged, and elderly groups, the MTRI method with different numbers of interpolated samples was used to estimate AWMs and local PWVs. Normalized root mean squared errors (NRMSEs) between the estimated and preset values of the AWMs and local PWVs were calculated and compared with ones without interpolation. The means of the NRMSEs for the AWMs and local PWVs based on the MTRI method with one interpolated sample decrease from 1.14% to 0.60% and 7.48% to 4.61%, respectively. Moreover, Bland-Altman analysis and coefficient of variation were used to validate the performance of the MTRI method based on the measured local PWVs of 30 healthy subjects. In conclusion, the reconstructive interpolation for the pulse wave estimation improves the accuracy and repeatability of the carotid local PWV measurement.
Full text links
Related Resources
Trending Papers
Renin-Angiotensin-Aldosterone System: From History to Practice of a Secular Topic.International Journal of Molecular Sciences 2024 April 5
Prevention and treatment of ischaemic and haemorrhagic stroke in people with diabetes mellitus: a focus on glucose control and comorbidities.Diabetologia 2024 April 17
British Society for Rheumatology guideline on management of adult and juvenile onset Sjögren disease.Rheumatology 2024 April 17
Albumin: a comprehensive review and practical guideline for clinical use.European Journal of Clinical Pharmacology 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app