Increasing Levels of Positive End-expiratory Pressure Cause Stepwise Biventricular Stroke Work Reduction in a Porcine Model.

Anesthesiology 2024 Februrary 2
BACKGROUND: Positive end-expiratory pressure (PEEP) is commonly applied to avoid atelectasis and improve oxygenation in patients during general anesthesia but affects cardiac pressures, volumes, and loading conditions through cardiorespiratory interactions. PEEP may therefore alter stroke work, which is the area enclosed by the pressure-volume loop and corresponds to the external work performed by the ventricles to eject blood. The low-pressure right ventricle may be even more susceptible to PEEP than the left ventricle. The authors hypothesized that increasing levels of PEEP would reduce stroke work in both ventricles.

METHODS: This was a prospective, observational, experimental study. Six healthy female pigs of approximately 60 kg were used. PEEP was stepwise increased from 0 to 5, 7, 9, 11, 13, 15, 17, and 20 cm H2O to cover the clinical spectrum of PEEP. Simultaneous, biventricular invasive pressure-volume loops, invasive blood pressures, and ventilator data were recorded.

RESULTS: Increasing PEEP resulted in stepwise reductions in left (5,740 ± 973 vs. 2,303 ± 1,154 mmHg · ml; P < 0.001) and right (2,064 ± 769 vs. 468 ± 133 mmHg · ml; P < 0.001) ventricular stroke work. The relative stroke work reduction was similar between the two ventricles. Left ventricular ejection fraction, afterload, and coupling were preserved. On the contrary, PEEP increased right ventricular afterload and caused right ventriculo-arterial uncoupling (0.74 ± 0.30 vs. 0.19 ± 0.13; P = 0.01) with right ventricular ejection fraction reduction (64 ± 8% vs. 37 ± 7%, P < 0.001).

CONCLUSIONS: A stepwise increase in PEEP caused stepwise reduction in biventricular stroke work. However, there are important interventricular differences in response to increased PEEP levels. PEEP increased right ventricular afterload leading to uncoupling and right ventricular ejection fraction decline. These findings may support clinical decision-making to further optimize PEEP as a means to balance between improving lung ventilation and preserving right ventricular function.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app