We have located links that may give you full text access.
Relationship between myopia control and amount of corneal refractive change after orthokeratology lens treatment.
BMC Ophthalmology 2023 October 31
BACKGROUND: To evaluate the relationship between amount of corneal refractive change (CRC) after wearing orthokeratology (Ortho-K) lenses and axial length (AL) growth.
METHODS: We retrospectively enrolled 77 patients (77 eyes) aged 8-14 years who wore Ortho-K lenses more than 12 months. We divided the patients into 2 subgroups: spherical equivalent (SE) ≤ -3.0 D and SE > -3.0 D subgroup. The sagittal and tangential curvature maps and corneal topographic data within the 8-mm diameter ring at the baseline and during follow-up visits after wearing Ortho-K lens were recorded in addition to the area, height, and volume of the CRC region. The AL data were recorded at the baseline and during follow-up visits. Multivariate linear regression was conducted to analyze associations between the area, height, and volume of the CRC region, AL elongation, and SE.
RESULTS: The average change in the CRC region was 9.77 ± 0.60 D in height, 16.66 ± 3.61 mm2 in area, and 87.47 ± 8.96 D*mm2 in volume on the tangential diagram after wearing Ortho-K lenses for 3 months. The AL showed a change of 0.19 ± 0.14 mm after 1 year of Ortho-K lens wear (P < 0.05). At 1 year, AL elongation was negatively correlated with the area (P = 0.019) and volume (P < 0.001) of the CRC region. At 1 year, for every 1-mm2 increase in the area and every 1-D*mm2 increase in the volume of the CRC region, the average AL elongation decreased by 0.01 mm and 0.002 mm, respectively, in the multivariate analysis. In patients with SE ≤ -3.0 D, AL elongation was negatively correlated with the CRC-region volume (β = -0.002, P = 0.018), and in patients with SE > -3.0 D, AL elongation was negatively correlated with the CRC-region area (β = -0.017, P = 0.016).
CONCLUSIONS: The AL elongation-control efficacy of Ortho-K lenses may be related to the area and volume of the CRC region.
METHODS: We retrospectively enrolled 77 patients (77 eyes) aged 8-14 years who wore Ortho-K lenses more than 12 months. We divided the patients into 2 subgroups: spherical equivalent (SE) ≤ -3.0 D and SE > -3.0 D subgroup. The sagittal and tangential curvature maps and corneal topographic data within the 8-mm diameter ring at the baseline and during follow-up visits after wearing Ortho-K lens were recorded in addition to the area, height, and volume of the CRC region. The AL data were recorded at the baseline and during follow-up visits. Multivariate linear regression was conducted to analyze associations between the area, height, and volume of the CRC region, AL elongation, and SE.
RESULTS: The average change in the CRC region was 9.77 ± 0.60 D in height, 16.66 ± 3.61 mm2 in area, and 87.47 ± 8.96 D*mm2 in volume on the tangential diagram after wearing Ortho-K lenses for 3 months. The AL showed a change of 0.19 ± 0.14 mm after 1 year of Ortho-K lens wear (P < 0.05). At 1 year, AL elongation was negatively correlated with the area (P = 0.019) and volume (P < 0.001) of the CRC region. At 1 year, for every 1-mm2 increase in the area and every 1-D*mm2 increase in the volume of the CRC region, the average AL elongation decreased by 0.01 mm and 0.002 mm, respectively, in the multivariate analysis. In patients with SE ≤ -3.0 D, AL elongation was negatively correlated with the CRC-region volume (β = -0.002, P = 0.018), and in patients with SE > -3.0 D, AL elongation was negatively correlated with the CRC-region area (β = -0.017, P = 0.016).
CONCLUSIONS: The AL elongation-control efficacy of Ortho-K lenses may be related to the area and volume of the CRC region.
Full text links
Related Resources
Trending Papers
Consensus Statement on Vitamin D Status Assessment and Supplementation: Whys, Whens, and Hows.Endocrine Reviews 2024 April 28
The Tricuspid Valve: A Review of Pathology, Imaging, and Current Treatment Options: A Scientific Statement From the American Heart Association.Circulation 2024 April 26
Intravenous infusion of dexmedetomidine during the surgery to prevent postoperative delirium and postoperative cognitive dysfunction undergoing non-cardiac surgery: a meta-analysis of randomized controlled trials.European Journal of Medical Research 2024 April 19
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Management of Diverticulitis: A Review.JAMA Surgery 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app