Add like
Add dislike
Add to saved papers

Accuracy of transdermal alcohol monitoring devices in a laboratory setting.

Alcohol and Alcoholism 2023 October 24
The development of transdermal alcohol sensors (TASs) presents a new method to monitor alcohol consumption with the ability to objectively measure data 24/7. We aimed to evaluate the accuracy of two TASs (BACtrack Skyn and Smart Start BARE) in a laboratory setting. Thirty-two adults received a dose of ethanol 0.56 g/kg body weight as a 20% solution while wearing the two TASs and provided Breath Alcohol Concentration (BrAC) measurements for 3.5 h postalcohol consumption. Pearson's correlations and repeated measures analysis of variance tests were conducted on the peak, time-to-peak, and area under the curve data. Bland-Altman plots were derived. A time series analysis and cross-correlations were conducted to adjust for time lag. Both TASs were able to detect alcohol and increase within 20 min. BrAC peaked significantly quicker than Skyn and BARE. BrAC and Skyn peaks were negatively significantly correlated (r = -0.381, P = .035, n = 31), while Skyn and BARE peaks were positively significantly correlated (r = 0.380, P = .038, n = 30). Repeated measures analysis of variance found a significant difference between BrAC, Skyn, and BARE (F(1.946, 852.301) = 459.873, P < .001)). A time series analysis found when BrAC-Skyn and BrAC-BARE were adjusted for the delay to peak, and there was still a significant difference. Failure rates: 1.7% (Skyn) and 4.8% (BARE). Some evidence was obtained for TAS validity as both consistently detected alcohol. Failure rates and time lag show improvements in older device generations. However, neither TAS presented strong equivalence to the breathalyser even when the lag time was adjusted. With further testing and technology advancements, TAS could be a potential alcohol monitoring tool. Two of the newest TAS devices were worn in laboratory conditions for one afternoon to compare their accuracy of alcohol monitoring to a breathalyser. Findings suggest that the two TASs (BACtrack Skyn and SmartStart BARE) recorded significantly similar data postalcohol consumption, but not with the breathalyser.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app