Differences in Atrial Substrate Localization using LGE-MRI, Electrogram Voltage and Conduction Velocity - A Cohort Study Using a Consistent Anatomical Reference Frame in Patients with Persistent Atrial Fibrillation.

BACKGROUND AND AIMS: Electro-anatomical voltage, conduction velocity (CV) mapping and late gadolinium enhancement magnetic resonance imaging (LGEMRI) have been correlated with atrial cardiomyopathy (ACM). However, the comparability between these modalities remains unclear. Aims: (1) Compare pathological substrate extent and location between current modalities. (2) Establish spatial histograms in a cohort. (3) Develop a new estimated optimised image intensity threshold (EOIIT) for LGE-MRI identifying patients with ACM. (4) Predict rhythm outcome after pulmonary vein isolation (PVI) for persistent atrial fibrillation.

METHODS: 36 ablation-naive persistent AF patients underwent LGE-MRI and high-definition electro-anatomical mapping in SR. LGE areas were classified using the UTAH, image intensity ratio (IIR > 1.20) and new EOIIT method for comparison to LVS and slow conduction areas <0.2 m/s. ROC analysis was used to determine LGE thresholds optimally matching LVS. ACM was defined as low voltage substrate (LVS) extent ≥ 5% of the left atrium (LA) surface at <0.5 mV.

RESULTS: The degree and distribution of detected pathological substrate varied significantly (p < 0.001) across the mapping modalities: 3% (IQR 0-12%) of the LA displayed LVS < 0.5 mV vs. 14% (3-25%) slow conduction areas < 0.2 m/s vs. 16% (6-32%) LGE with the UTAH method vs. 17% (11-24%) using IIR > 1.20, with most discrepancies on the posterior LA. Optimised image intensity thresholds and each patient's mean blood pool intensity correlated linearly (R2 = 0.89, p < 0.001). Concordance between LGE-MRI-based and LVS-based ACM diagnosis improved with the novel EOIIT applied at the anterior LA (83% sensitivity, 79% specificity, AUC: 0.89) in comparison to the UTAH method (67% sensitivity, 75% specificity, AUC: 0.81) and IIR > 1.20 (75% sensitivity, 62% specificity, AUC: 0.67).

CONCLUSION: Discordances in detected pathological substrate exist between LVS, CV and LGE-MRI in the LA, irrespective of the LGE detection method. The new EOIIT method improves concordance of LGE-MRI-based ACM diagnosis with LVS in ablation-naive AF patients but discrepancy remains particularly on the posterior wall. All methods may enable prediction of rhythm outcome after PVI in patients with persistent AF.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app