Add like
Add dislike
Add to saved papers

γ-H2AX and phospho-ATM enzyme-linked immunosorbent assays as biodosimetry methods for radiation exposure assessment: a pilot study.

In the event of a radiological incident, a fast and accurate biological dosimetry (biodosimetry) method for evaluating people who have been potentially exposed to ionising radiation is crucial. Among the many biodosimetry methods available, the immunodetection of phosphorylated H2AX (γ-H2AX) stands as a promising method to be used in the triage of patients exposed to radiation. Currently, the most common way to measure γ-H2AX levels is through fluorescence microscopy. In this pilot study, we assessed the feasibility of using an enzyme-linked immunosorbent assay (ELISA) for quantifying γ-H2AX for biodosimetry purposes. Moreover, the usefulness of measuring phosphorylated ATM (pATM) levels through ELISA for biodosimetry was also evaluated. Blood samples were obtained from three male donors (38 y) and were irradiated with 60Co (0, 1, 2 and 6 Gy). Peripheral blood mononuclear cells (PBMCs) were isolated and lysed before measuring γ-H2AX, total H2AX protein and pATM using ELISA kits. The dicentric chromosome assay (DCA) using whole blood was also performed for comparison. Data from all donors at each dose were pooled before statistical analysis. The ratio of γ-H2AX/total H2AX and pATM levels increased in a radiation-dose-dependent manner. The average γ-H2AX/total H2AX ratios were 0.816 ± 0.219, 0.830 ± 0.685, 1.276 ± 1.151 and 1.606 ± 1.098, whereas the average levels of pATM were 59.359 ± 3.740, 63.366 ± 0.840, 66.273 ± 2.603 and 69.936 ± 4.439, in PBMCs exposed to 0, 1, 2 and 6 Gy, respectively. The linear-quadratic dose-response calibration curve for DCA was Y = 0.0017 (±0.0010) + 0.0251 (±0.0142) × D + 0.0342 (±0.0039) × D2  $\boldsymbol{Y}=\mathbf{0.0017}\left(\pm \mathbf{0.0010}\right)+\mathbf{0.0208}\left(\pm \mathbf{0.0218}\right)\times \boldsymbol{D}+\mathbf{0.0350}\left(\pm \mathbf{0.0050}\right)\times{\boldsymbol{D}}^{\mathbf{2}}$. Overall, despite a large variability in the ratio of γ-H2AX/total H2AX among donors, the present study revealed the suitability of using the ratio of γ-H2AX/total H2AX and pATM for biodosimetry. Still, more research with a larger group of subjects is necessary to construct a reliable calibration curve for the ratio of γ-H2AX/total H2AX and pATM levels for biodosimetry.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app