We have located links that may give you full text access.
Position of the ISTENT Inject ® Trabecular Micro-Bypass System Visualized with the NIDEK GS-1 Gonioscope-A Postoperative Analysis.
Journal of Clinical Medicine 2023 August 9
Glaucoma is one of the leading causes of irreversible blindness globally and is characterized by the gradual loss of retinal ganglion cells. The primary risk factor for the development and progression of glaucoma is increased intraocular pressure (IOP). Numerous surgical interventions exist to lower IOP should conservative therapy fail. One trend in recent years has been minimally invasive glaucoma surgery (MIGS) as an alternative to traditional methods. The ISTENT inject® is an ab interno trabecular micro-bypass implant designed to be implanted through the trabecular meshwork into the Schlemm's canal to lower IOP. The aim of the study was the postoperative visualization and description of the positioning of the ISTENT inject® using automated circumferential goniophotography. Patients with symptomatic cataracts and mild to moderate primary open-angle glaucoma (POAG), pseudoexfoliation glaucoma (PEX), and pigment-dispersion glaucoma were included who underwent combined cataract surgery with the ISTENT inject® and received postoperative automated gonioscopy with the NIDEK Gonioscope GS-1 to visualize the location of the implant. Twenty-four implants of 14 eyes in 11 patients could be visualized. Out of the implants, 14.3% were in the trabecular meshwork, 46.4% were at the border between the trabecular meshwork and scleral spur, 25% were below the trabecular meshwork, and 14.3% of the implants were not detectable in the gonioscopy. In the overall cohort, a statistically significant IOP reduction was found over the 12-month postoperative observation period. Even in three eyes, in each of which both stents were located below the trabecular meshwork, an IOP reduction over 12 months was observed compared to the baseline IOP. In this study, vertical two-dimensional positioning of the ISTENT inject® was performed for the first time using NIDKE GS-1 automated 360° goniophotography. The method is suitable for postoperative visualization, control, and documentation of positioning after ISTENT inject® implantation. Further studies are needed to analyze the correlation between positioning of the ISTENT inject® in the chamber angle and postoperative IOP reduction.
Full text links
Related Resources
Trending Papers
Guillain-Barré syndrome: History, pathogenesis, treatment, and future directions.European Journal of Neurology 2024 May 17
Angiotensin Receptor Blocker-Neprilysin Inhibitor for Heart Failure with Reduced Ejection Fraction.Pharmacological Research : the Official Journal of the Italian Pharmacological Society 2024 May 12
The Therapy and Management of Heart Failure with Preserved Ejection Fraction: New Insights on Treatment.Cardiac Failure Review 2024
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app