We have located links that may give you full text access.
Laser scattering centrifugal liquid sedimentation method for the accurate quantitative analysis of mass-based size distributions of colloidal silica.
Analytical Sciences : the International Journal of the Japan Society for Analytical Chemistry 2023 March 27
This paper proposes a laser scattering centrifugal liquid sedimentation (LS-CLS) method for the accurate quantitative analysis of the mass-based size distributions of colloidal silica. The optics comprised a laser diode light source and multi-pixel photon-counting detector for detecting scattered light intensity. The unique optics can only detect the light scattered by a sample through the interception of irradiated light. The developed centrifugal liquid sedimentation (CLS) method comprised a light-emitting diode and silicon photodiode detector for detecting transmittance light attenuation. The CLS apparatus could not accurately measure quantitative volume- or mass-based size distribution of poly-dispersed suspensions, such as colloidal silica, because the detecting signal includes both transmitted and scattered light. The LS-CLS method exhibited improved quantitative performance. Moreover, the LS-CLS system allowed the injection of samples with concentrations higher than that permitted by other particle size distribution measurement systems with particle size classification units using size-exclusion chromatography or centrifugal field-flow fractionation. The proposed LS-CLS method achieved an accurate quantitative analysis of the mass-based size distribution using both centrifugal classification and laser scattering optics. In particular, the system could measure the mass-based size distribution of approximately 20 mg mL-1 poly-dispersed colloidal silica samples, such as in a mixture of the four mono-dispersed colloidal silica, with high resolution and precision, thereby demonstrating high quantitative performance. The measured size distributions were compared with those observed through transmission electron microscopy. The proposed system can be used in practical setups to achieve a reasonable degree of consistency for determining particle size distribution in industrial applications.
Full text links
Related Resources
Trending Papers
Angiotensin Receptor Blocker-Neprilysin Inhibitor for Heart Failure with Reduced Ejection Fraction.Pharmacological Research : the Official Journal of the Italian Pharmacological Society 2024 May 12
Hemodynamic Support in Sepsis.Anesthesiology 2024 June 2
The Therapy and Management of Heart Failure with Preserved Ejection Fraction: New Insights on Treatment.Cardiac Failure Review 2024
European Respiratory Society Clinical Practice Guideline on symptom management for adults with serious respiratory illness.European Respiratory Journal 2024 May 9
Axillary Surgery for Breast Cancer in 2024.Cancers 2024 April 24
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app