We have located links that may give you full text access.
Clinical-Instrumental Results and Analysis of Functional Activity Restoration in Professional Athletes After Lumbar Total Disk Replacement.
World Neurosurgery 2021 July
OBJECTIVE: To analyze the clinical and biomechanical outcome of professional athletes after lumbar total disk replacement, with a focus on restoration of the functional activity.
METHODS: This nonrandomized retrospective single-center study included 11 professional athletes who underwent lumbar disc replacement surgery using the prosthesis M6-L (Spinal Kinetics, Schaffhausen, Switzerland). The average postoperative follow-up was 3.18 ± 1.14 years. The following outcomes were evaluated: intensity of pain in the lumbar spine and lower limbs, Oswestry Disability Index, Short-Form 36, complications, time of return to previous sports activity, range of movement, degree of lumbar lordosis, degenerative changes of the adjacent levels, and degree of heterotopic ossification.
RESULTS: The operated patients reported significant decrease of pain on visual analog scale (P < 0.001) as well as significant improvement of Oswestry Disability Index (P = 0.001) and Short-Form 36 (P < 0.001). For the duration of follow-up, the patients maintained segmental range of motion at L4-L5 (P = 0.04) and L5-S1 (P = 0.03) levels. There was also some statistically insignificant increase of global lumbar lordosis (P = 0.84). We did not identify any significant degeneration of the adjacent intervertebral disks (P > 0.05) or progression of the facet joint degenerative changes at the implantation level and in the adjacent segments (P > 0.05). One patient (9.1%) developed grade I heterotopic ossification 5 years after surgery and in 1 patient (9.1%), a lesion of superior hypogastric plexus was recorded. The average time of return to previous sports activity was 9.72 ± 3.03 weeks.
CONCLUSIONS: Total lumbar disc replacement using M6-L prosthesis in professional athletes made it possible to achieve statistically significant reduction of pain and facilitated early return to normal sports activities. In our opinion, preservation of movement of the operated lumbar segment can help to reduce the mechanical stress with beneficial impact on the rate of degeneration of the adjacent level.
METHODS: This nonrandomized retrospective single-center study included 11 professional athletes who underwent lumbar disc replacement surgery using the prosthesis M6-L (Spinal Kinetics, Schaffhausen, Switzerland). The average postoperative follow-up was 3.18 ± 1.14 years. The following outcomes were evaluated: intensity of pain in the lumbar spine and lower limbs, Oswestry Disability Index, Short-Form 36, complications, time of return to previous sports activity, range of movement, degree of lumbar lordosis, degenerative changes of the adjacent levels, and degree of heterotopic ossification.
RESULTS: The operated patients reported significant decrease of pain on visual analog scale (P < 0.001) as well as significant improvement of Oswestry Disability Index (P = 0.001) and Short-Form 36 (P < 0.001). For the duration of follow-up, the patients maintained segmental range of motion at L4-L5 (P = 0.04) and L5-S1 (P = 0.03) levels. There was also some statistically insignificant increase of global lumbar lordosis (P = 0.84). We did not identify any significant degeneration of the adjacent intervertebral disks (P > 0.05) or progression of the facet joint degenerative changes at the implantation level and in the adjacent segments (P > 0.05). One patient (9.1%) developed grade I heterotopic ossification 5 years after surgery and in 1 patient (9.1%), a lesion of superior hypogastric plexus was recorded. The average time of return to previous sports activity was 9.72 ± 3.03 weeks.
CONCLUSIONS: Total lumbar disc replacement using M6-L prosthesis in professional athletes made it possible to achieve statistically significant reduction of pain and facilitated early return to normal sports activities. In our opinion, preservation of movement of the operated lumbar segment can help to reduce the mechanical stress with beneficial impact on the rate of degeneration of the adjacent level.
Full text links
Related Resources
Trending Papers
Angiotensin Receptor Blocker-Neprilysin Inhibitor for Heart Failure with Reduced Ejection Fraction.Pharmacological Research : the Official Journal of the Italian Pharmacological Society 2024 May 12
Drug Therapy for Acute and Chronic Heart Failure with Preserved Ejection Fraction with Hypertension: A State-of-the-Art Review.American Journal of Cardiovascular Drugs : Drugs, Devices, and Other Interventions 2024 April 5
Guillain-Barré syndrome: History, pathogenesis, treatment, and future directions.European Journal of Neurology 2024 May 17
The Therapy and Management of Heart Failure with Preserved Ejection Fraction: New Insights on Treatment.Cardiac Failure Review 2024
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app