We have located links that may give you full text access.
Performance of a new preloaded fiducial needle to guide radiation therapy of upper gastrointestinal cancers.
Endoscopy 2018 December 22
BACKGROUND: Insertion of fiducials to outline the targeted lesion allows image-guided radiotherapy, and is best achieved by endoscopic ultrasound (EUS). This study is a performance comparison of the new EUS-guided preloaded fiducial needle against Visicoil fiducials.
METHODS: Technical success, visibility score, procedural time, costs, and complications for patients who underwent EUS-guided fiducial placement in upper gastrointestinal malignancies were prospectively collected.
RESULTS: 60 patients with upper gastrointestinal cancers had fiducials (14 Visicoil; 46 preloaded fiducials) inserted for image-guided radiotherapy. Technical success was 100 %, with a shorter mean (standard deviation) insertion time of 0.94 minutes (0.28 minutes) vs. 5.5 minutes (1.9 minutes; P < 0.001) and higher visibility score on fluoroscopy of 2 vs. 1.18 ( P < 0.001) in the preloaded group. Neither group had major complications related to fiducial insertion. The cost of consumables per patient was lower in the preloaded group at US$480 (US$124) vs. US$643 (US$123; P < 0.001).
CONCLUSION: Fiducial insertion for image-guided radiotherapy using the new preloaded needle is associated with 100 % technical success, shorter insertion time, and higher visibility, and is more cost-effective than the Visicoil system.
METHODS: Technical success, visibility score, procedural time, costs, and complications for patients who underwent EUS-guided fiducial placement in upper gastrointestinal malignancies were prospectively collected.
RESULTS: 60 patients with upper gastrointestinal cancers had fiducials (14 Visicoil; 46 preloaded fiducials) inserted for image-guided radiotherapy. Technical success was 100 %, with a shorter mean (standard deviation) insertion time of 0.94 minutes (0.28 minutes) vs. 5.5 minutes (1.9 minutes; P < 0.001) and higher visibility score on fluoroscopy of 2 vs. 1.18 ( P < 0.001) in the preloaded group. Neither group had major complications related to fiducial insertion. The cost of consumables per patient was lower in the preloaded group at US$480 (US$124) vs. US$643 (US$123; P < 0.001).
CONCLUSION: Fiducial insertion for image-guided radiotherapy using the new preloaded needle is associated with 100 % technical success, shorter insertion time, and higher visibility, and is more cost-effective than the Visicoil system.
Full text links
Related Resources
Trending Papers
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Autoimmune Hemolytic Anemias: Classifications, Pathophysiology, Diagnoses and Management.International Journal of Molecular Sciences 2024 April 13
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app