Deep learning in the cross-time-frequency domain for sleep staging from a single lead electrocardiogram.

Physiological Measurement 2018 November 24
OBJECTIVE: This study classifies sleep stages from a single lead electrocardiogram (ECG) using beat detection, cardiorespiratory coupling in the time-frequency domain and a deep convolutional neural network (CNN). 
 
 Approach: An ECG-derived respiration (EDR) signal and synchronous beat-to-beat heart rate variability (HRV) time series were derived from the ECG using previously described robust algorithms. A measure of cardiorespiratory coupling (CRC) was extracted by calculating the coherence and cross-spectrogram of the EDR and HRV signal in five-minute windows. A CNN was then trained to classify the sleep stages (wake, rapid-eye-movement (REM) sleep, non-REM (NREM) light sleep and NREM deep sleep) from the corresponding CRC spectrograms. A support vector machine was then used to combine the output of CNN with the other features derived from the ECG, including phase-rectified signal averaging (PRSA), sample entropy, as well as standard spectral and temporal HRV measures. The MIT-BIH Polysomnographic Database (SLPDB), the PhysioNet/Computing in Cardiology Challenge 2018 database (CinC2018) and the Sleep Heart Health Study (SHHS) database, all expert-annotated for sleep stages, were used to train and validate the algorithm. 
 
 Main results: Ten-fold cross validation results showed that the proposed algorithm achieved an accuracy (Acc) of 75.4% and a Cohen's kappa coefficient of <i>K</i> = 0.54 on the out of sample validation data in the classification of Wake, REM, NREM light and deep sleep in SLPDB. This rose to Acc = 81.6% and <i>K</i> = 0.63 for the classification of Wake, REM sleep and NREM sleep and Acc = 85.1% and <i>K</i> = 0.68 for the classification of NREM sleep versus REM/wakefulness in SLPDB. 
 
 Significance: The proposed ECG-based sleep stage classification approach that represents the highest reported results on non-electroencephalographic data and uses datasets over 10 times larger than those in previous studies. By using a state-of-the-art QRS detector and deep learning model, the system does not require human annotation and can therefore be scaled for mass analysis.&#13.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app