Combination of left atrial appendage closure and catheter ablation in a single procedure for patients with atrial fibrillation: Multicenter experience.
BACKGROUND/PURPOSE: Experience in procedures combining left atrial appendage (LAA) closure (LAAC) and catheter ablation (CA) was scarce in Chinese nonvalvular atrial fibrillation (AF) patients with high risks for stroke and bleeding. We aimed to investigate the efficacy and safety of the combination therapy with LAAC and AF CA in a single procedure based on the multicenter data and medium-term follow-up results.
METHODS: A total of 122 AF patients with a mean CHA2 DS2 -VASc score of 4.3 ± 1.4 and HAS-BLED score of 3.3 ± 1.0 were enrolled. The Watchman (n = 83) devices were implanted either before or after AF ablations in the same procedure, while the Amplatzer Cardiac Plug (ACP, n = 39) devices were implanted immediately after CA. AF recurrence and transesophageal echocardiography results were evaluated.
RESULTS: All devices were successfully implanted and acute complete LAA occlusions were achieved in 115 (94.3%) of patients. Neither acute nor chronic peri-device leaks greater than 5 mm were detected. Oral anticoagulation was held in all patients but two with asymptomatic device-related thrombi, which were resolved after prolonged anticoagulation. AF-free success rate without antiarrhythmic drugs was 76.2% after a mean follow-up of 11.5 ± 6.8 months. No serious complications were observed during the follow-up.
CONCLUSION: The combination therapy with LAAC and AF ablation in a single procedure was efficacious and safe in the Chinese symptomatic AF population with high risk for stroke and bleeding.
METHODS: A total of 122 AF patients with a mean CHA2 DS2 -VASc score of 4.3 ± 1.4 and HAS-BLED score of 3.3 ± 1.0 were enrolled. The Watchman (n = 83) devices were implanted either before or after AF ablations in the same procedure, while the Amplatzer Cardiac Plug (ACP, n = 39) devices were implanted immediately after CA. AF recurrence and transesophageal echocardiography results were evaluated.
RESULTS: All devices were successfully implanted and acute complete LAA occlusions were achieved in 115 (94.3%) of patients. Neither acute nor chronic peri-device leaks greater than 5 mm were detected. Oral anticoagulation was held in all patients but two with asymptomatic device-related thrombi, which were resolved after prolonged anticoagulation. AF-free success rate without antiarrhythmic drugs was 76.2% after a mean follow-up of 11.5 ± 6.8 months. No serious complications were observed during the follow-up.
CONCLUSION: The combination therapy with LAAC and AF ablation in a single procedure was efficacious and safe in the Chinese symptomatic AF population with high risk for stroke and bleeding.
Full text links
Related Resources
Trending Papers
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Autoimmune Hemolytic Anemias: Classifications, Pathophysiology, Diagnoses and Management.International Journal of Molecular Sciences 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app