Journal Article
Multicenter Study
Add like
Add dislike
Add to saved papers

Immune-inflammatory response after bioresorbable vascular scaffold implantation in patients with acute myocardial infarction with ST elevation in a long-term perspective.

A higher rate of bioresorbable vascular scaffold (BVS) thrombosis has been observed after device implantation compared to implantation of permanent metallic stents in recently published studies. The mechanism of BVS thrombosis is currently under debate. To assess whether the immune-inflammatory response after BVS implantation is a potential trigger of BVS thrombosis. The PRAGUE-19 study was an academic study that enrolled consecutive patients with ST-segment elevation myocardial infarction (STEMI) with the intention to implant a BVS. A laboratory sub-study included 49 patients with an implanted BVS (of which 38 underwent the complete 2-year follow-up) and 52 patients having an implanted permanent metallic stent as the control group (of which 30 underwent the complete 2-year follow-up). Samples for inflammatory markers [high-sensitivity C-reactive protein (hs-CRP), interleukin-6 (IL-6) and tumor necrosis factor-alpha (TNF-α)] were taken before BVS or stent implantation, on days 1 and 2 after device implantation and at 1 month and 2 years for a clinical control. The primary combined clinical endpoint of the sub-study (death, reinfarction or target vessel revascularization) occurred in 4.08% of the BVS group and 7.69% of the control group (p = 0.442) during the 2-year follow-up period, with overall mortality of 2.04% in the BVS group and 1.92% in the control group (p = 0.966). Definite BVS thrombosis occurred in one patient in the subacute phase; there was no late or very late thrombosis. Two definite stent thromboses were observed in the control group: one in the subacute phase and the other in the late phase. Baseline inflammatory marker levels did not differ between the groups. Lower levels of IL-6 and hs-CRP were observed in the BVS group compared to the control group (12.02 ± 5.94 vs. 15.21 ± 5.33 pg/ml; p < 0.01; 3952.9 ± 1704.75 ng/ml vs. 4507.49 ± 1190.01 ng/ml; p = 0.037, respectively) on days 1 and 2 (12.01 ± 6.31 vs. 13.85 ± 6.01 pg/ml; p = 0.089; 4447.92 ± 1325.31 ng/ml vs. 4637.03 ± 1290.99 ng/ml; p = 0.255, respectively). No differences in IL-6 or hs-CRP were observed after 1 month or 2 years in the clinical control. Levels of TNF-α did not differ between the groups in the early period after BVS or metallic stent implantation, nor during follow-up. The immune-inflammatory response is lower during the early phase after BVS implantation compared to that after metallic stent implantation, but the responses did not differ in the long term.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app