Correlation between Dt/V derived from ionic dialysance and blood-driven Kt/V of urea in African-American hemodialysis patients, based on body weight and ultrafiltration volume.
Clinical Kidney Journal 2018 October
BACKGROUND: The Dt/V obtained by using ionic dialysance (D) as a surrogate for urea clearance (K) is a well-validated adjunct measure of hemodialysis adequacy, with a variable level of correlation with urea-based Kt/V. However, this correlation has not been examined based on patients' body size and ultrafiltration (UF) volume during the dialysis session.
METHODS: Simultaneous evaluations of online Dt/V and single-pool variable-volume urea Kt/V were made. Patients were categorized into three subgroups based on their weight (<60, 60-80 and ≥80 kg), body mass index (<25, 25-30 and >30 kg/m2 ) and UF volume (<1.5, 1.5-3 and >3 L). The correlation between Dt/V and Kt/V was evaluated for the entire cohort per dialysis session in each subgroup.
RESULTS: Mean Kt/V was greater than the mean Dt/V (1.72 versus 1.50, P < 0.001), with an overall correlation r value of 0.602. This correlation was stronger in the medium weight group versus lower and higher weights. The correlation between Dt/V and Kt/V was inversely related to the UF volume ( r = 0.698, 0.621 and 0.558 for those with UF volume of <1.5, 1.5-3.0 and >3 L, respectively). A total of 99.3% of patients with Dt/V of >1.2 also had Kt/V >1.2 and 9.5% of those with Dt/V <1.2 had their Kt/V <1.2.
CONCLUSIONS: There is a moderate degree of correlation between Dt/V and Kt/V in African-American hemodialysis patients, which is impacted by body size and UF volume. A Dt/V of >1.2 strongly predicts adequate dialysis as defined by Kt/V of >1.2.
METHODS: Simultaneous evaluations of online Dt/V and single-pool variable-volume urea Kt/V were made. Patients were categorized into three subgroups based on their weight (<60, 60-80 and ≥80 kg), body mass index (<25, 25-30 and >30 kg/m2 ) and UF volume (<1.5, 1.5-3 and >3 L). The correlation between Dt/V and Kt/V was evaluated for the entire cohort per dialysis session in each subgroup.
RESULTS: Mean Kt/V was greater than the mean Dt/V (1.72 versus 1.50, P < 0.001), with an overall correlation r value of 0.602. This correlation was stronger in the medium weight group versus lower and higher weights. The correlation between Dt/V and Kt/V was inversely related to the UF volume ( r = 0.698, 0.621 and 0.558 for those with UF volume of <1.5, 1.5-3.0 and >3 L, respectively). A total of 99.3% of patients with Dt/V of >1.2 also had Kt/V >1.2 and 9.5% of those with Dt/V <1.2 had their Kt/V <1.2.
CONCLUSIONS: There is a moderate degree of correlation between Dt/V and Kt/V in African-American hemodialysis patients, which is impacted by body size and UF volume. A Dt/V of >1.2 strongly predicts adequate dialysis as defined by Kt/V of >1.2.
Full text links
Related Resources
Trending Papers
Autoimmune Hemolytic Anemias: Classifications, Pathophysiology, Diagnoses and Management.International Journal of Molecular Sciences 2024 April 13
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Finerenone: From the Mechanism of Action to Clinical Use in Kidney Disease.Pharmaceuticals 2024 March 27
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app