Stability of intrinsic rhythm in pacemaker-dependent patients during pacemaker replacement: Can we predict the need for temporary pacing?
Journal of Arrhythmia 2018 August
Background: In pacemaker-dependent patients, the risk of asystole must be managed during device replacement. This study aimed to examine whether we could predict the indication for temporary pacing (TP) during the generator replacement.
Methods: We studied 105 consecutive patients who underwent pacemaker replacement due to battery depletion at Juntendo Nerima Hospital between September 2005 and December 2016. We examined the relationship between the stability of the intrinsic rhythm (IR) during pacemaker replacement and several clinical factors including age, gender, sick sinus syndrome or atrioventricular (AV) block, duration of pacing, structural heart disease, use of anti-arrhythmic drugs, and the presence/absence of a stable IR (>40 bpm) at the outpatient clinic (OPC) just before pacemaker replacement.
Results: Of the 105 patients, we excluded 1 patient who required TP because of bradycardia-dependent torsades de points. Therefore, we evaluated 104 patients for the indication for TP. TP was underwent in 19 patients (18%) because of an absence or instability of the IR during pacemaker replacement. The indication for TP was significantly correlated with AV block (84% vs 48%, P = .0044) and the absence of a stable IR at the last OPC visit (89% vs 24%, P < .0001). For predicting the indication for TP, the following values of no stable IR at the last OPC visit were obtained: 89% sensitivity, 77% specificity, 46% positive predictive value, and 97% negative predictive value.
Conclusions: The presence of a stable IR at the last OPC visit was a good predictor (97%) of no indication for TP during pacemaker replacement.
Methods: We studied 105 consecutive patients who underwent pacemaker replacement due to battery depletion at Juntendo Nerima Hospital between September 2005 and December 2016. We examined the relationship between the stability of the intrinsic rhythm (IR) during pacemaker replacement and several clinical factors including age, gender, sick sinus syndrome or atrioventricular (AV) block, duration of pacing, structural heart disease, use of anti-arrhythmic drugs, and the presence/absence of a stable IR (>40 bpm) at the outpatient clinic (OPC) just before pacemaker replacement.
Results: Of the 105 patients, we excluded 1 patient who required TP because of bradycardia-dependent torsades de points. Therefore, we evaluated 104 patients for the indication for TP. TP was underwent in 19 patients (18%) because of an absence or instability of the IR during pacemaker replacement. The indication for TP was significantly correlated with AV block (84% vs 48%, P = .0044) and the absence of a stable IR at the last OPC visit (89% vs 24%, P < .0001). For predicting the indication for TP, the following values of no stable IR at the last OPC visit were obtained: 89% sensitivity, 77% specificity, 46% positive predictive value, and 97% negative predictive value.
Conclusions: The presence of a stable IR at the last OPC visit was a good predictor (97%) of no indication for TP during pacemaker replacement.
Full text links
Related Resources
Trending Papers
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Autoimmune Hemolytic Anemias: Classifications, Pathophysiology, Diagnoses and Management.International Journal of Molecular Sciences 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app