We have located links that may give you full text access.
Journal Article
Validation Studies
Calibrated kallikrein generation in human plasma.
Clinical Biochemistry 2016 October
OBJECTIVES: The physiological role of the contact system remains inconclusive. No obvious clinical complications have been observed for factor XII (FXII), prekallikrein (PK), or high molecular weight kininogen deficiencies even though the contact system in vitro is associated with coagulation, fibrinolysis, and inflammation. A global generation assay measuring the initial phase of the contact system could be a valuable tool for studies of its physiological role.
DESIGN AND METHODS: We investigated whether such a method could be developed using the principle of the Calibrated Automated Thrombin generation method as a template.
RESULTS: A suitable kallikrein specific fluorogenic substrate was identified (KM=0.91mM, kcat=19s(-1)), and kallikrein generation could be measured in undiluted plasma when silica was added as activator. Disturbing effects, including substrate depletion and the inner-filter effect, however, affected the signal. These problems were corrected for by external calibration with α2-macroglobulin-kallikrein complexes. Selectivity studies of the substrate, experiments with FXII and PK depleted plasmas, and plasma with high or low complement C1-esterase inhibitor activity indicated that the obtained and calibrated signal predominantly was related to FXII-dependent kallikrein activity.
CONCLUSIONS: The findings described show that establishment of a kallikrein generation method is possible. Potentially, this setup could be used for clinical studies of the contact system.
DESIGN AND METHODS: We investigated whether such a method could be developed using the principle of the Calibrated Automated Thrombin generation method as a template.
RESULTS: A suitable kallikrein specific fluorogenic substrate was identified (KM=0.91mM, kcat=19s(-1)), and kallikrein generation could be measured in undiluted plasma when silica was added as activator. Disturbing effects, including substrate depletion and the inner-filter effect, however, affected the signal. These problems were corrected for by external calibration with α2-macroglobulin-kallikrein complexes. Selectivity studies of the substrate, experiments with FXII and PK depleted plasmas, and plasma with high or low complement C1-esterase inhibitor activity indicated that the obtained and calibrated signal predominantly was related to FXII-dependent kallikrein activity.
CONCLUSIONS: The findings described show that establishment of a kallikrein generation method is possible. Potentially, this setup could be used for clinical studies of the contact system.
Full text links
Related Resources
Trending Papers
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Autoimmune Hemolytic Anemias: Classifications, Pathophysiology, Diagnoses and Management.International Journal of Molecular Sciences 2024 April 13
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app