We have located links that may give you full text access.
Utility of three-dimensional computed tomography for the surgical management of rib fractures.
Journal of Trauma and Acute Care Surgery 2015 March
BACKGROUND: Surgical stabilization of flail chest is increasingly recognized as a valid approach to improve pulmonary mechanics in selected trauma patients. The use of two-dimensional (2D) computed tomography (CT) has become almost universal in the assessment of blunt chest trauma and multiple rib fractures. We hypothesized that three-dimensional (3D) CT adds valuable information to the preoperative plan for fixation of rib fractures.
METHODS: Using a retrospective cohort of 35 consecutive adult patients with flail chest requiring surgery, we evaluated the intraobserver and interobserver reliability of plain radiographs, 2D CT and 3D CT, for the identification of rib fractures and identified how often the surgical plan changed with the addition of the information provided by the 3D CT. Two fellowship-trained orthopedic trauma surgeons who regularly operate on rib fractures in their clinical practice and were not involved in the treatment of the study population evaluated the radiographic data.
RESULTS: Intraobserver and interobserver reliability was excellent for both 2D CT and 3D CT and was the highest for 2D CT. Overall, 2D CT had the highest diagnostic accuracy for detecting rib fractures as compared with plain radiographs and 3D CT. However, 3D CT changed the surgical tactic in 65.7% of the cases.
CONCLUSION: We conclude that 3D CT is not as accurate as 2D CT for rib fracture diagnostic purposes; it seems to be an important tool for the preoperative planning of rib fracture fixation.
LEVEL OF EVIDENCE: Diagnostic study, level II.
METHODS: Using a retrospective cohort of 35 consecutive adult patients with flail chest requiring surgery, we evaluated the intraobserver and interobserver reliability of plain radiographs, 2D CT and 3D CT, for the identification of rib fractures and identified how often the surgical plan changed with the addition of the information provided by the 3D CT. Two fellowship-trained orthopedic trauma surgeons who regularly operate on rib fractures in their clinical practice and were not involved in the treatment of the study population evaluated the radiographic data.
RESULTS: Intraobserver and interobserver reliability was excellent for both 2D CT and 3D CT and was the highest for 2D CT. Overall, 2D CT had the highest diagnostic accuracy for detecting rib fractures as compared with plain radiographs and 3D CT. However, 3D CT changed the surgical tactic in 65.7% of the cases.
CONCLUSION: We conclude that 3D CT is not as accurate as 2D CT for rib fracture diagnostic purposes; it seems to be an important tool for the preoperative planning of rib fracture fixation.
LEVEL OF EVIDENCE: Diagnostic study, level II.
Full text links
Related Resources
Trending Papers
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Autoimmune Hemolytic Anemias: Classifications, Pathophysiology, Diagnoses and Management.International Journal of Molecular Sciences 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app