The effect of PMMA-based protein-leaking dialyzers on plasma homocysteine levels.

BACKGROUND: Hyperhomocysteinemia is a well-recognized independent risk factor for cardiovascular disease in end-stage renal disease (ESRD) patients. Since homocysteine (Hcy) largely binds to serum proteins (80 to 90%), in this study we investigated the possibility that polymethylmethacrylate (PMMA)-based protein-leaking dialyzers could reduce total plasma Hcy (tHcy) levels in ESRD patients.

METHODS: Two matched groups of patients (N = 13) showing mild to intermediate hyperhomocysteinemia on standard hemodialysis (HD) with conventional non-protein-leaking dialyzers were included. In the control group membranes were maintained the same, while the study group was switched to protein-leaking dialyzers (BK-F series; Toray, Japan) and studied for 6 months. tHcy was measured by high performance liquid chromatography (HPLC) at baseline and after 1, 3, and 6 months. Proteins and Hcy were also measured in the spent dialysate.

RESULTS: The pre-HD levels of tHcy in the control group remained close to baseline values (26.6 +/- 5.0 micromol/L), while in the study group at 1, 3, and 6 months they decreased from a baseline value (in micrormol/L) of 25.3 +/- 5.9 to 21.5 +/- 4.5, 16.9 +/- 4.0, and 17.2 +/- 4.2, respectively (P < 0.01 for values at 3 and 6 months vs. baseline). The intra-HD drop of tHcy (Delta HDHcy) slightly but progressively decreased during the 3 steps on protein-leaking dialyzers and a positive correlation was found between Delta HDHcy and pre-HD levels of tHcy. In spent dialysate samples from protein-leaking dialyzer-treated patients, the amount of protein-bound Hcy (bHcy) was approximately 10 times higher than in non-protein-leaking dialyzers, but the Delta HDHcy observed in non-protein-leaking dialyzers and protein-leaking dialyzers was comparable. Serum proteins and albumin were only slightly affected by protein-leaking dialyzers.

CONCLUSION: This study demonstrates that protein-leaking dialyzers used with a pure diffusive technique significantly lower pre-HD tHcy (approximately 33% of starting levels after 3 months of treatment) in ESRD patients. A possible underlying mechanism for this effect could be the removal of large molecular weight solutes responsible for a defective metabolism of the Hcy, as the removal of bHcy with protein-leaking dialyzers seems not sufficient, per se, to explain this steady reduction of tHcy levels in pre-HD.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app