Add like
Add dislike
Add to saved papers

Spatiotemporal Deep Learning-Based Cine Loop Quality Filter for Handheld Point-of-Care Echocardiography.

The reliability of automated image interpretation of point-of-care (POC) echocardiography scans depends on the quality of the acquired ultrasound data. This work reports on the development and validation of spatiotemporal deep learning models to assess the suitability of input ultrasound cine loops collected using a handheld echocardiography device for processing by an automated quantification algorithm (e.g. ejection fraction estimation). POC echocardiograms (n=885 DICOM cine loops from 175 patients) from two sites were collected using a handheld ultrasound device and annotated for image quality at the frame-level. Attributes of high-quality frames for left ventricular (LV) quantification included a temporally-stable LV, reasonable coverage of LV borders, and good contrast between the borders and chamber. Attributes of low-quality frames included temporal instability of the LV and/or imaging artifacts (e.g., lack of contrast, haze, reverberation, acoustic shadowing). Three different neural network architectures were investigated - (a) frame-level convolutional neural network (CNN) which operates on individual echo frames (VectorCNN), (b) single-stream sequence-level CNN which operates on a sequence of echo frames (VectorCNN+LSTM) and (c) two-stream sequence-level CNNs which operate on a sequence of echo and optical flow frames (VectorCNN+LSTM+Average, VectorCNN+LSTM+MinMax, and VectorCNN+LSTM+ConvPool). Evaluation on a sequestered test dataset containing 76 DICOM cine loops with 16,914 frames showed that VectorCNN+LSTM can effectively utilize both spatial and temporal information to regress the quality of an input frame (accuracy: 0.925, sensitivity = 0.860, specificity = 0.952), compared to the frame-level VectorCNN that only utilizes spatial information in that frame (accuracy: 0.903, sensitivity = 0.791, specificity = 0.949). Furthermore, an independent sample t-test indicated that the cine loops classified to be of adequate quality by the VectorCNN+LSTM model had a statistically significant lower bias in the automatically estimated EF (mean bias = - 3.73 ± 7.46 %, versus a clinically obtained reference EF) compared to the loops classified as inadequate (mean bias = -15.92 ± 12.17 %) (p = 0.007). Thus, cine loop stratification using the proposed spatiotemporal CNN model improves the reliability of automated point-of-care echocardiography image interpretation.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app