We have located links that may give you full text access.
Spatiotemporal Deep Learning-Based Cine Loop Quality Filter for Handheld Point-of-Care Echocardiography.
The reliability of automated image interpretation of point-of-care (POC) echocardiography scans depends on the quality of the acquired ultrasound data. This work reports on the development and validation of spatiotemporal deep learning models to assess the suitability of input ultrasound cine loops collected using a handheld echocardiography device for processing by an automated quantification algorithm (e.g. ejection fraction estimation). POC echocardiograms (n=885 DICOM cine loops from 175 patients) from two sites were collected using a handheld ultrasound device and annotated for image quality at the frame-level. Attributes of high-quality frames for left ventricular (LV) quantification included a temporally-stable LV, reasonable coverage of LV borders, and good contrast between the borders and chamber. Attributes of low-quality frames included temporal instability of the LV and/or imaging artifacts (e.g., lack of contrast, haze, reverberation, acoustic shadowing). Three different neural network architectures were investigated - (a) frame-level convolutional neural network (CNN) which operates on individual echo frames (VectorCNN), (b) single-stream sequence-level CNN which operates on a sequence of echo frames (VectorCNN+LSTM) and (c) two-stream sequence-level CNNs which operate on a sequence of echo and optical flow frames (VectorCNN+LSTM+Average, VectorCNN+LSTM+MinMax, and VectorCNN+LSTM+ConvPool). Evaluation on a sequestered test dataset containing 76 DICOM cine loops with 16,914 frames showed that VectorCNN+LSTM can effectively utilize both spatial and temporal information to regress the quality of an input frame (accuracy: 0.925, sensitivity = 0.860, specificity = 0.952), compared to the frame-level VectorCNN that only utilizes spatial information in that frame (accuracy: 0.903, sensitivity = 0.791, specificity = 0.949). Furthermore, an independent sample t-test indicated that the cine loops classified to be of adequate quality by the VectorCNN+LSTM model had a statistically significant lower bias in the automatically estimated EF (mean bias = - 3.73 ± 7.46 %, versus a clinically obtained reference EF) compared to the loops classified as inadequate (mean bias = -15.92 ± 12.17 %) (p = 0.007). Thus, cine loop stratification using the proposed spatiotemporal CNN model improves the reliability of automated point-of-care echocardiography image interpretation.
Full text links
Related Resources
Trending Papers
Angiotensin Receptor Blocker-Neprilysin Inhibitor for Heart Failure with Reduced Ejection Fraction.Pharmacological Research : the Official Journal of the Italian Pharmacological Society 2024 May 12
Drug Therapy for Acute and Chronic Heart Failure with Preserved Ejection Fraction with Hypertension: A State-of-the-Art Review.American Journal of Cardiovascular Drugs : Drugs, Devices, and Other Interventions 2024 April 5
Guillain-Barré syndrome: History, pathogenesis, treatment, and future directions.European Journal of Neurology 2024 May 17
The Therapy and Management of Heart Failure with Preserved Ejection Fraction: New Insights on Treatment.Cardiac Failure Review 2024
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app