Add like
Add dislike
Add to saved papers

Geometric Analysis of the Gore Excluder Conformable Endoprosthesis in the Infrarenal Aortic Neck: One Year Results of the EXCeL Registry.

OBJECTIVE: The Gore Excluder Conformable Endoprosthesis (CEXC) is designed to treat challenging infrarenal anatomy because of its active angulation control, repositionability, and enhanced conformability. This study evaluated 30 day and one year position and apposition of the CEXC in the infrarenal neck.

METHODS: Patients treated with the CEXC between 2018 and 2022 with an available 30 day computed tomography angiography (CTA) were selected from four hospitals in a prospective registry. Endograft apposition (shortest apposition length [SAL]) and position (shortest fabric distance [SFD]) were assessed on the 30 day and one year CTAs. Maximum infrarenal aortic curvature was compared between the pre-operative and post-operative CTAs to evaluate conformability of the CEXC.

RESULTS: There were 87 patients with a 30 day CTA, and for 56 of these patients the one year CTA was available. Median (interquartile range [IQR]) pre-operative neck length was 22 mm (IQR 15, 32) and infrarenal angulation was 52° (IQR 31, 72). Median SAL was 21.2 mm (IQR 14.0, 29.3) at 30 days for all included patients. The SAL in 13 patients (15%) was < 10 mm at 30 days, and one patient had a SAL of 0 mm and a type Ia endoleak. There was no significant difference in SAL between patients within and outside instructions for use. The SAL significantly increased by 1.1 mm (IQR -2.3, 4.7; p = .042) at 1 year. The SAL decreased in seven patients (13%), increased in 13 patients (23%), and remained stable in 36 patients (64%). Median SFD was 2.0 mm (IQR 0.5, 3.6) at 30 days, which slightly increased by 0.3 mm (IQR -0.5, 1.8; p = .019) at 1 year. One patient showed migration (SFD increase ≥ 5 mm). Median endograft tilt was 15.8° (IQR 9.7, 21.4). Pre-operative maximum infrarenal curvature was 36 m-1 (IQR 26, 56) and did not significantly change thereafter.

CONCLUSION: In most patients, the CEXC was implanted close to the renal arteries, and sufficient (≥ 10 mm) post-operative apposition was acquired at 30 days, which slightly increased at one year. Post-operative endograft tilt was relatively low, and aortic geometry remained unchanged after implantation of the CEXC, probably due to its high conformability.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app