We have located links that may give you full text access.
A Direct Assessment of Noninvasive Continuous Blood Pressure Monitoring in the Emergency Department and Intensive Care Unit.
Journal of Emergency Nursing : JEN : Official Publication of the Emergency Department Nurses Association 2024 April 19
INTRODUCTION: Noninvasive continuous blood pressure monitoring has the potential to improve patient treatment in the hospital setting. Such noninvasive devices can be applied earlier in the treatment process to empower nurses and clinicians to react more quickly to patient deterioration with the added benefit of eliminating the risks associated with invasive monitoring. However, emerging technologies must be capable of reproducing current clinical measures for medical decision making.
METHODS: This study aimed to determine the usability and willingness of nurses to implement a noninvasive continuous blood pressure monitoring device. The secondary aim directly compared the systolic blood pressure, diastolic blood pressure, and mean arterial pressure values recorded by the device (VitalStream; CareTaker Medical LLC, Charlottesville, VA) with the "gold standard" brachial cuff and arterial line measures recorded in the emergency department and intensive care unit settings.
RESULTS: VitalStream was similarly received by nurses in the emergency department and intensive care setting, but ultimately had greater promotion from emergency nurses. Despite some statistical similarity between measurement methodologies, all direct comparisons were found to not meet the Association for the Advancement of Medical Instrumentation 2008 and Association for the Advancement of Medical Instrumentation / European Society of Hypertension / International Organization for Standardization 2019 consensus statement criteria for acceptable blood pressure measure differences between the VitalStream and "gold standard" clinical measures. In all instances, the standard deviation of the Bland-Altman bias exceeded 8 mm Hg with less than 85% of paired differences falling within 10 mm Hg of the "gold standard."
DISCUSSION: Taken together, the tested device requires additional postprocessing for medical decision making in trauma or emergent care.
METHODS: This study aimed to determine the usability and willingness of nurses to implement a noninvasive continuous blood pressure monitoring device. The secondary aim directly compared the systolic blood pressure, diastolic blood pressure, and mean arterial pressure values recorded by the device (VitalStream; CareTaker Medical LLC, Charlottesville, VA) with the "gold standard" brachial cuff and arterial line measures recorded in the emergency department and intensive care unit settings.
RESULTS: VitalStream was similarly received by nurses in the emergency department and intensive care setting, but ultimately had greater promotion from emergency nurses. Despite some statistical similarity between measurement methodologies, all direct comparisons were found to not meet the Association for the Advancement of Medical Instrumentation 2008 and Association for the Advancement of Medical Instrumentation / European Society of Hypertension / International Organization for Standardization 2019 consensus statement criteria for acceptable blood pressure measure differences between the VitalStream and "gold standard" clinical measures. In all instances, the standard deviation of the Bland-Altman bias exceeded 8 mm Hg with less than 85% of paired differences falling within 10 mm Hg of the "gold standard."
DISCUSSION: Taken together, the tested device requires additional postprocessing for medical decision making in trauma or emergent care.
Full text links
Related Resources
Trending Papers
Revascularization Strategy in Myocardial Infarction with Multivessel Disease.Journal of Clinical Medicine 2024 March 27
Intravenous infusion of dexmedetomidine during the surgery to prevent postoperative delirium and postoperative cognitive dysfunction undergoing non-cardiac surgery: a meta-analysis of randomized controlled trials.European Journal of Medical Research 2024 April 19
The Tricuspid Valve: A Review of Pathology, Imaging, and Current Treatment Options: A Scientific Statement From the American Heart Association.Circulation 2024 April 26
Consensus Statement on Vitamin D Status Assessment and Supplementation: Whys, Whens, and Hows.Endocrine Reviews 2024 April 28
Management of Diverticulitis: A Review.JAMA Surgery 2024 April 18
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app