Add like
Add dislike
Add to saved papers

The effect of different alignment strategies on trochlear orientation after total knee arthroplasty.

PURPOSE: When planning and delivering total knee arthroplasty (TKA), there are multiple coronal alignment strategies such as functional alignment (FA), kinematic alignment (KA), mechanical and adjusted mechanical alignment (MA, aMA). Recent three-dimensional and robotic-assisted surgery (RAS) studies have demonstrated that KA potentially better restores the trochlear anatomy than MA. The purpose of this study was to compare the restoration of the native trochlear orientation in patients undergoing RAS TKA using four different alignment strategies. It was hypothesised that FA would result in the lowest number of outliers.

METHODS: This is a prospective study of 200 patients undergoing RAS-TKA with a single implant. All patients were analysed for MA and KA prebalancing, and 157 patients received aMA and 43 patients FA with intraoperative balancing. Preoperative transverse computed tomography scans were used to determine the posterior condylar axis (PCA), lateral trochlear inclination (LTI) angle, sulcus angle (SA) and anterior trochlear line (ATL) angle. Implant measurements were obtained using a photographic analysis. Intraoperative software data combined with implant data and preoperative measurements were used to calculate the differences. Outliers were defined as ≥3° of alteration. Trochlea dysplasia was defined as LTI < 12°.

RESULTS: Native transepicondylar PCA had a median of 2°, LTI 18°, SA 137°, ATL 4°. LTI outliers were observed in 47%-60% of cases, with KA < FA < aMA < MA. For ATL, the range of outliers was 40.5%-85%, KA < FA < aMA < MA. SA produced 81% of outliers. Of all median angle values, only LTI when using KA was not significantly altered compared to the native knee.

CONCLUSION: There is a significant alteration of trochlear orientation after TKA, regardless of the alignment strategy used. KA produced the lowest, but a substantial, number of outliers. The uniform design of implants causes the surgeon to compromise on balance in flexion versus trochlear position. The clinical relevance of this compromise requires further clinical investigations.

LEVEL OF EVIDENCE: Level II, prospective cohort study.

Full text links

We have located open access text paper links.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app