We have located links that may give you full text access.
Patient satisfaction with ultrasound, whole-body CT and whole-body diffusion-weighted MRI for pre-operative ovarian cancer staging: a multicenter prospective cross-sectional survey.
International Journal of Gynecological Cancer 2024 March 27
BACKGROUND: In addition to the diagnostic accuracy of imaging methods, patient-reported satisfaction with imaging methods is important.
OBJECTIVE: To report a secondary outcome of the prospective international multicenter Imaging Study in Advanced ovArian Cancer (ISAAC Study), detailing patients' experience with abdomino-pelvic ultrasound, whole-body contrast-enhanced computed tomography (CT), and whole-body diffusion-weighted magnetic resonance imaging (WB-DWI/MRI) for pre-operative ovarian cancer work-up.
METHODS: In total, 144 patients with suspected ovarian cancer at four institutions in two countries (Italy, Czech Republic) underwent ultrasound, CT, and WB-DWI/MRI for pre-operative work-up between January 2020 and November 2022. After having undergone all three examinations, the patients filled in a questionnaire evaluating their overall experience and experience in five domains: preparation before the examination, duration of examination, noise during the procedure, radiation load of CT, and surrounding space. Pain perception, examination-related patient-perceived unexpected, unpleasant, or dangerous events ('adverse events'), and preferred method were also noted.
RESULTS: Ultrasound was the preferred method by 49% (70/144) of responders, followed by CT (38%, 55/144), and WB-DWI/MRI (13%, 19/144) (p<0.001). The poorest experience in all domains was reported for WB-DWI/MRI, which was also associated with the largest number of patients who reported adverse events (eg, dyspnea). Patients reported higher levels of pain during the ultrasound examination than during CT and WB-DWI/MRI (p<0.001): 78% (112/144) reported no pain or mild pain, 19% (27/144) moderate pain, and 3% (5/144) reported severe pain (pain score >7 of 10) during the ultrasound examination. We did not identify any factors related to patients' preferred method.
CONCLUSION: Ultrasound was the imaging method preferred by most patients despite being associated with more pain during the examination in comparison with CT and WB-DWI/MRI.
TRIAL REGISTRATION NUMBER: NCT03808792.
OBJECTIVE: To report a secondary outcome of the prospective international multicenter Imaging Study in Advanced ovArian Cancer (ISAAC Study), detailing patients' experience with abdomino-pelvic ultrasound, whole-body contrast-enhanced computed tomography (CT), and whole-body diffusion-weighted magnetic resonance imaging (WB-DWI/MRI) for pre-operative ovarian cancer work-up.
METHODS: In total, 144 patients with suspected ovarian cancer at four institutions in two countries (Italy, Czech Republic) underwent ultrasound, CT, and WB-DWI/MRI for pre-operative work-up between January 2020 and November 2022. After having undergone all three examinations, the patients filled in a questionnaire evaluating their overall experience and experience in five domains: preparation before the examination, duration of examination, noise during the procedure, radiation load of CT, and surrounding space. Pain perception, examination-related patient-perceived unexpected, unpleasant, or dangerous events ('adverse events'), and preferred method were also noted.
RESULTS: Ultrasound was the preferred method by 49% (70/144) of responders, followed by CT (38%, 55/144), and WB-DWI/MRI (13%, 19/144) (p<0.001). The poorest experience in all domains was reported for WB-DWI/MRI, which was also associated with the largest number of patients who reported adverse events (eg, dyspnea). Patients reported higher levels of pain during the ultrasound examination than during CT and WB-DWI/MRI (p<0.001): 78% (112/144) reported no pain or mild pain, 19% (27/144) moderate pain, and 3% (5/144) reported severe pain (pain score >7 of 10) during the ultrasound examination. We did not identify any factors related to patients' preferred method.
CONCLUSION: Ultrasound was the imaging method preferred by most patients despite being associated with more pain during the examination in comparison with CT and WB-DWI/MRI.
TRIAL REGISTRATION NUMBER: NCT03808792.
Full text links
Related Resources
Trending Papers
Haemodynamic monitoring during noncardiac surgery: past, present, and future.Journal of Clinical Monitoring and Computing 2024 April 31
2024 AHA/ACC/AMSSM/HRS/PACES/SCMR Guideline for the Management of Hypertrophic Cardiomyopathy: A Report of the American Heart Association/American College of Cardiology Joint Committee on Clinical Practice Guidelines.Circulation 2024 May 9
Obesity pharmacotherapy in older adults: a narrative review of evidence.International Journal of Obesity 2024 May 7
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app