Add like
Add dislike
Add to saved papers

Development of an opportunistic diagnostic prediction algorithm for osteoporosis and fragility fracture risk estimates from forearm radiographs (The OFFER1 Study).

JBMR Plus 2024 April
Osteoporosis and associated fractures are an increasingly prevalent concern with an ageing population. This study reports testing of IBEX Bone Health (IBEX BH) software, applied following acquisition of forearm radiographs. IBEX Bone Health analyses the radiograph to measure areal bone mineral density (aBMD) at the examination site. A non-randomized cross-sectional study design was performed involving 261 (254 after exclusions) participants (112/142 m/f; mean age 70.8 years (SD+/-9.0); 53 with osteoporosis). They underwent posterior-anterior distal forearm radiographs; dual X-ray absorptiometry (DXA) of the wrists, hips, and lumbar spine; and questionnaires exploring clinical risk factors. IBEX Bone Health automatically identifies regions of interest (ROI) at the ultra-distal (UD) and distal third (TD) regions of the radius. Analysis investigated area under the receiver operating characteristics curve performance of IBEX BH for prediction of (i) osteoporosis (based on clinical reporting of the hip and spine DXA) and (ii) treatment recommendations by Fracture Risk Assessment Tool (FRAX) inclusive of neck of femur (NoF) areal bone mineral density (aBMD) results following National Osteoporosis Guideline Group (NOGG) guidelines. Area under the receiver operating characteristics curve for osteoporosis prediction at the UD and TD ROIs were 0.86 (99% confidence interval (CI) [0.80, 0.91]) and 0.81 (99% CI [0.75, 0.88]), respectively. Area under the receiver operating characteristics curve for treatment recommendation using FRAX inclusive of NoF aBMD at the UD and TD ROIs were 0.95 (99% CI [0.91, 1.00]) and 0.97 (99% CI [0.93,1.00]), respectively. With a matched sensitivity to FRAX (without NoF aBMD) 0.93 (99% CI [0.78, 0.99]), IBEX BH predicted at the UD and TD ROIs recommended treatment outcomes by NOGG guidelines using FRAX (with NoF aBMD) with specificity 0.89 (99% CI 0.83, 0.94]) and 0.93 (99% CI [0.87, 0.97]), respectively. This is compared with 0.60 (99% CI [0.51, 0.69]) for FRAX (without NoF aBMD). Results demonstrate the potential clinical utility of IBEX BH as an opportunistic screening tool.

Full text links

We have located open access text paper links.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app