IMPORTANCE: Pulse oximetry, a ubiquitous vital sign in modern medicine, has inequitable accuracy that disproportionately affects Black and Hispanic patients, with associated increases in mortality, organ dysfunction, and oxygen therapy. Although the root cause of these clinical performance discrepancies is believed to be skin tone, previous retrospective studies used self-reported race or ethnicity as a surrogate for skin tone.
OBJECTIVE: To determine the utility of objectively measured skin tone in explaining pulse oximetry discrepancies.
DESIGN SETTING AND PARTICIPANTS: Admitted hospital patients at Duke University Hospital were eligible for this prospective cohort study if they had pulse oximetry recorded up to 5 minutes prior to arterial blood gas (ABG) measurements. Skin tone was measured across sixteen body locations using administered visual scales (Fitzpatrick Skin Type, Monk Skin Tone, and Von Luschan), reflectance colorimetry (Delfin SkinColorCatch [L*, individual typology angle {ITA}, Melanin Index {MI}]), and reflectance spectrophotometry (Konica Minolta CM-700D [L*], Variable Spectro 1 [L*]).
MAIN OUTCOMES AND MEASURES: Mean directional bias, variability of bias, and accuracy root mean square (A RMS ), comparing pulse oximetry and ABG measurements. Linear mixed-effects models were fitted to estimate mean directional bias while accounting for clinical confounders.
RESULTS: 128 patients (57 Black, 56 White) with 521 ABG-pulse oximetry pairs were recruited, none with hidden hypoxemia. Skin tone data was prospectively collected using 6 measurement methods, generating 8 measurements. The collected skin tone measurements were shown to yield differences among each other and overlap with self-reported racial groups, suggesting that skin tone could potentially provide information beyond self-reported race. Among the eight skin tone measurements in this study, and compared to self-reported race, the Monk Scale had the best relationship with differences in pulse oximetry bias (point estimate: -2.40%; 95% CI: -4.32%, - 0.48%; p= 0.01) when comparing patients with lighter and dark skin tones.
CONCLUSIONS AND RELEVANCE: We found clinical performance differences in pulse oximetry, especially in darker skin tones. Additional studies are needed to determine the relative contributions of skin tone measures and other potential factors on pulse oximetry discrepancies.
KEY POINTS: Question: Can skin tone capture information beyond race to help explain pulse oximetry discrepancies? Findings: Pulse oximetry bias across races seems to persist across skin tone when measured using administered visual scales, reflectance colorimetry, or reflectance spectrophotometry. Among the eight skin tone measurements in this study, and compared to self-reported race, the Monk Scale seemed to best correlate with pulse oximetry bias when comparing patients with lighter and dark skin tones. Meaning: Compared to self-reported race, skin tone is associated with some pulse oximetry discrepancies; we recommend using skin tone to assist the regulatory clearance of equitable pulse oximeters.
OBJECTIVE: To determine the utility of objectively measured skin tone in explaining pulse oximetry discrepancies.
DESIGN SETTING AND PARTICIPANTS: Admitted hospital patients at Duke University Hospital were eligible for this prospective cohort study if they had pulse oximetry recorded up to 5 minutes prior to arterial blood gas (ABG) measurements. Skin tone was measured across sixteen body locations using administered visual scales (Fitzpatrick Skin Type, Monk Skin Tone, and Von Luschan), reflectance colorimetry (Delfin SkinColorCatch [L*, individual typology angle {ITA}, Melanin Index {MI}]), and reflectance spectrophotometry (Konica Minolta CM-700D [L*], Variable Spectro 1 [L*]).
MAIN OUTCOMES AND MEASURES: Mean directional bias, variability of bias, and accuracy root mean square (A RMS ), comparing pulse oximetry and ABG measurements. Linear mixed-effects models were fitted to estimate mean directional bias while accounting for clinical confounders.
RESULTS: 128 patients (57 Black, 56 White) with 521 ABG-pulse oximetry pairs were recruited, none with hidden hypoxemia. Skin tone data was prospectively collected using 6 measurement methods, generating 8 measurements. The collected skin tone measurements were shown to yield differences among each other and overlap with self-reported racial groups, suggesting that skin tone could potentially provide information beyond self-reported race. Among the eight skin tone measurements in this study, and compared to self-reported race, the Monk Scale had the best relationship with differences in pulse oximetry bias (point estimate: -2.40%; 95% CI: -4.32%, - 0.48%; p= 0.01) when comparing patients with lighter and dark skin tones.
CONCLUSIONS AND RELEVANCE: We found clinical performance differences in pulse oximetry, especially in darker skin tones. Additional studies are needed to determine the relative contributions of skin tone measures and other potential factors on pulse oximetry discrepancies.
KEY POINTS: Question: Can skin tone capture information beyond race to help explain pulse oximetry discrepancies? Findings: Pulse oximetry bias across races seems to persist across skin tone when measured using administered visual scales, reflectance colorimetry, or reflectance spectrophotometry. Among the eight skin tone measurements in this study, and compared to self-reported race, the Monk Scale seemed to best correlate with pulse oximetry bias when comparing patients with lighter and dark skin tones. Meaning: Compared to self-reported race, skin tone is associated with some pulse oximetry discrepancies; we recommend using skin tone to assist the regulatory clearance of equitable pulse oximeters.
Full text links
Related Resources
Trending Papers
Consensus Statement on Vitamin D Status Assessment and Supplementation: Whys, Whens, and Hows.Endocrine Reviews 2024 April 28
The Tricuspid Valve: A Review of Pathology, Imaging, and Current Treatment Options: A Scientific Statement From the American Heart Association.Circulation 2024 April 26
Intravenous infusion of dexmedetomidine during the surgery to prevent postoperative delirium and postoperative cognitive dysfunction undergoing non-cardiac surgery: a meta-analysis of randomized controlled trials.European Journal of Medical Research 2024 April 19
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Management of Diverticulitis: A Review.JAMA Surgery 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app